Ex Solenoid / Alarm Driver PR 5203B-U9
UL 913-approved version for US market only. Features 1- or 2-channel configuration as solenoid driver for intrinsically safe areas with 3.75 kVAC galvanic isolation and digital control.
Product Overview
- 1- or 2-channel solenoid driver for intrinsically safe areas
- 3.75 kVAC galvanic isolation (3-/5-port configuration)
- Digitally controlled operation
- UL 913-approved for US market
- Maximum frequency: 20 Hz
Environmental Specifications
| Operating temperature |
-20°C to +60°C |
| Calibration temperature |
20...28°C |
| Relative humidity |
< 95% RH (non-condensing) |
| Protection degree |
IP20 |
Mechanical Specifications
| Dimensions (HxWxD) |
109 x 23.5 x 130 mm |
| Weight approx. |
230 g |
| DIN rail type |
DIN EN 60715/35 mm |
| Wire size |
0.13...2.08 mm² AWG 26...14 stranded wire |
| Screw terminal torque |
0.5 Nm |
Electrical Specifications
Power Supply
| Supply voltage, universal |
21.6...253 VAC, 50...60 Hz or 19.2...300 VDC |
| Fuse |
400 mA SB / 250 VAC |
| Max. required power |
≤ 4 W (2 channels) |
| Internal power dissipation |
≤ 2 W (2 channels) |
Isolation Voltage
| Isolation voltage, test / working |
3.75 kVAC / 250 VAC |
| PELV/SELV |
IEC 61140 |
Input Specifications
NPN and Mechanical Switch
| Trigger level LOW |
≤ 4.0 VDC |
| Trigger level HIGH |
≥ 7.0 VDC |
| Max. external voltage |
28 VDC |
| Input impedance |
3.48 kΩ |
PNP
| Trigger level LOW |
≤ 4.0 VDC |
| Trigger level HIGH |
≥ 7.0 VDC |
| Max. external voltage |
28 VDC |
| Input impedance |
3.48 kΩ |
Output Specifications
| Output voltage |
See I.S. data in manual |
| Output current |
See I.S. data in manual |
| Output ripple |
< 40 mVRMS |
Compliance & Approvals
Authority Requirements
| EMC |
2014/30/EU |
| LVD |
2014/35/EU |
Certifications
| c UL us, UL 508 |
05122003-E233311 |
| c UL us, UL 913 |
05122003-E233311 |
Programming: DIP switches
EMC immunity influence: < ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span