Engineered for the strict demands of digital infrastructure, this 250kVA 11kV to 0.4kV dry type distribution transformer provides a dedicated power step-down solution within server rooms and IT facilities. Its epoxy-resin encapsulated high-voltage coils eliminate fire and leakage risks associated with liquid-filled units, making it a truly safe choice for placing power directly near sensitive server racks, PDUs, and UPS systems. The transformer is built for continuous, uninterrupted operation, featuring a robust design that minimizes noise, withstands network harmonics, and requires virtually no maintenance over its long service life.
| Parameter | Specification |
|---|---|
| Rated Power | 250 kVA |
| Primary Voltage | 11 kV |
| Secondary Voltage | 0.4 kV (400V, Three-Phase) |
| Frequency | 50/60 Hz (Customizable) |
| Vector Group | Dyn11 |
| Cooling Method | AN (Natural Air) / AF (Forced Air for 150% overload) |
| Insulation Class | F (155°C) or H (180°C), with Class F temperature rise limit for extended life |
| Winding Material | HV Copper, LV Aluminum/Copper Foil (Customizable) |
| Impedance Voltage | 4% or 6% (as per project specification) |
| Tapping Range | ±2*2.5% (Off-circuit tap changer on HV side) |
| Partial Discharge Level | ≤ 10 pC (Tested per IEC standards) |
| Enclosure Protection | IP23 (Indoor standard) up to IP54 on request |
| Standards Compliance | IEC 60076, GB/T 10228, and equivalent international standards |
Addressing Critical Power Needs Through Focused Design
Server rooms and data centers present specific operating conditions that demand specialized electrical design. The high concentration of sensitive microprocessors, UPS battery banks, and precision cooling creates a need for a stable, clean, and never-failing power source. This transformer incorporates several technical measures to guarantee performance under these conditions.
A: Yes, it is specifically rated for indoor installation. The epoxy-resin insulation is fire-resistant and self-extinguishing, producing no toxic smoke. Without oil, there is no containment pit needed. It can occupy dedicated electrical rooms or secure corners of server halls with minimal clearance, providing power right where it is consumed.
A: Absolutely. It features a Dyn11 vector group and foil-type secondary winding, which is a proven design for withstanding the neutral currents and harmonic heating associated with UPS equipment. This design prevents thermal aging and allows the transformer to operate reliably within your total cost of ownership expectations.
A: The high-voltage coils are cast under vacuum in a solid resin compound. This eliminates air voids that can lead to partial discharge over time. Additionally, the transformer inherently limits fault currents and is highly resilient to short circuits, ensuring that one component short does not translate into a catastrophic fire or complete bus failure affecting your entire critical infrastructure.
A: The scheduled maintenance is minimal. There are no oil samples, gasket replacements, or pumps. We recommend an annual visual inspection to check terminal connections and a periodic dust cleaning if the unit is not inside an IP54 enclosure. The sealed coil surface can simply be wiped down.
A: The noise is remarkably low, achieved through a precision-stepped lap core and high-quality silicon steel. Under natural air cooling, it operates quietly and without any fan noise. If you opt for the AF package for enhanced overload, the fan control is temperature-activated and runs only when required, preserving the acoustic environment.
A: Yes. As a custom transformer manufacturer, we configure enclosure ingress protection, cable entry (top/bottom), and busbar orientation to ensure a seamless interface with your switchgear and busway system. We work directly with EPC projects to meet precise site specifications.
Specify your power infrastructure today — Contact us for a custom 250kVA dry type transformer quotation.