Product Overview
The Broadcom ACPL-x2xL series comprises optically coupled logic gates designed for reliable digital signal isolation. These devices feature CMOS output stages and integrated Schmitt trigger input stages for logic-compatible waveforms without external shaping. They offer a wide operating supply voltage range (2.7V to 5.5V) and a guaranteed performance over an extended temperature range of 40C to +105C. With high common-mode transient immunity (25 kV/s at 1000V) and various safety and regulatory approvals, these optocouplers are suitable for applications such as microprocessor system interfaces, ground loop elimination, and high-speed line receivers.
Product Attributes
- Brand: Broadcom
- Certifications: UL 1577 recognized, CSA Approval, IEC/EN 60747-5-5
- Material Group: IIIa (DIN VDE 0110, 1/89)
- Pollution Degree: 2 (DIN VDE 0110/39)
Technical Specifications
| Model | Package Type | Description | UL 1577 Rating | IEC/EN 60747-5-5 |
| ACPL-M21L | SO-5 | Single-channel | 3750 VRMS for 1 minute | (Option 060 and 560 only) |
| ACPL-021L | SO-8 | Single-channel | 3750 VRMS for 1 minute | (Option 060 and 560 only) |
| ACPL-024L | SO-8 | Dual-channel | 3750 VRMS for 1 minute | (Option 060 and 560 only) |
| ACPL-W21L | Stretched SO-6 | Single-channel | 5000 VRMS for 1 minute | (Option 060 and 560 only) |
| ACPL-K24L | Stretched SO-8 | Dual-channel | 5000 VRMS for 1 minute | (Option 060 and 560 only) |
| Parameter | Symbol | Min. | Typ. | Max. | Units | Conditions |
| Supply Voltage | VDD | 2.7 | | 5.5 | V | Recommended Operating Conditions |
| Operating Temperature | TA | -40 | | 105 | C | Absolute Maximum Ratings & Recommended Operating Conditions |
| Speed | | | 5 | | MBd | Typical |
| Pulse Width Distortion | PWD | | | 200 | ns | Max |
| Propagation Delay Skew | tpsk | | | 220 | ns | Max |
| Propagation Delay | tp | | | 250 | ns | Max |
| Common Mode Rejection | | 25 | | | kV/s | Min at VCM = 1000V |
| Low Power Supply Current (per channel) | IDD | | 1.1 | | mA | Max |
| Low Forward Current | IF | 1.6 | | | mA | Min |
| Input-Output Insulation Voltage (ACPL-M21L/024L/021L) | VISO | 3750 | | | Vrms | For 1 minute |
| Input-Output Insulation Voltage (ACPL-W21L/K24L) | VISO | 5000 | | | Vrms | For 1 minute |
| Input-Output Resistance | RI-O | | 1012 | | | VI-O = 500V |
| Input-Output Capacitance | CI-O | | 0.6 | | pF | f = 1 MHz, TA = 25C |
| Minimum External Air Gap (Clearance) | L(101) | 4.8 | | 8 | mm | ACPL-M21L/024L/021L: 5mm, ACPL-W21L/K24L: 8mm |
| Minimum External Tracking (Creepage) | L(102) | 4.8 | | 8 | mm | ACPL-M21L/024L/021L: 5mm, ACPL-W21L/K24L: 8mm |
| Comparative Tracking Index | CTI | | 175 | | V | DIN IEC 112/VDE 0303 Part 1 |
| Maximum Working Insulation Voltage | VIORM | 567 | | 1140 | Vpeak | ACPL-M21L/024L/021L: 567Vpeak, ACPL-W21L/K24L: 1140Vpeak |
2410121853_Broadcom-ACPL-M21L-500E_C691952.pdf