Model Number :
GA50UB010ABA
Enclosure Rating :
IP20 Protected Chassis
Payment Terms :
D/A, D/P, T/T, Western Union, MoneyGram,
Heavy Duty Power :
2 HP / 1.5 kW
Price :
USD 310/Unit
Packaging Details :
original packing
Motor Control :
Induction and Permanent-Magnet Motor Control
Delivery Time :
3-5Days
Input Power :
200–240 VAC, Single Phase
Brand Name :
YASKAWA
Braking Transistor :
Built In
Supply Ability :
20Units per Month
Normal Duty Power :
3 HP / 2.2 kW
Heavy Duty Output Current :
8.0 A
Model :
GA50UB010ABA
Normal Duty Output Current :
9.6 A
MOQ :
1
Place of Origin :
USA
Description

Product Overview

The Yaskawa GA50UB010ABA is a GA500 variable frequency drive designed to operate from a 200 to 240 VAC single-phase input supply and control a compatible three-phase motor. It provides a Normal Duty rating of 3 HP or 2.2 kW with 9.6 A output current. Under Heavy Duty selection, it is rated for 2 HP or 1.5 kW with 8.0 A output current.

This configuration is useful where three-phase utility power is unavailable but the machine requires variable-speed operation of a three-phase motor. It must not be confused with GA50U2010ABA, which provides similar output ratings but requires a three-phase input supply.

Model-Specific Rating and Selection

GA50UB010ABA is positioned above GA50UB006ABA in the single-phase-input GA500 range. Its 9.6 A Normal Duty rating supports moderate-overload applications at the 3 HP level, while the 8 A Heavy Duty rating applies to more demanding 2 HP machinery.

Motor horsepower alone is insufficient for selection. Compare the motor full-load current with the correct duty rating and review starting torque, acceleration time, load inertia and stopping frequency. The upstream single-phase circuit must also have adequate capacity for the drive input demand.

Motor Control Technology

The GA500 platform offers V/f and open-loop vector control for induction motors and control capability for compatible permanent-magnet motors. Open-loop vector control can improve torque production and speed stability without encoder feedback when motor information and tuning are correct.

The drive output is intended for a compatible three-phase motor, not a single-phase capacitor-start motor. Enter motor voltage, current, frequency, speed and power from the actual motor nameplate. Autotuning should be completed in accordance with the selected motor and control method.

Control, Safety and Communication

Configurable digital and analog terminals support run commands, direction selection, external frequency references, interlocks and operating-status feedback. Embedded RS-485 supports MEMOBUS/Modbus RTU. EtherNet/IP, PROFINET, EtherCAT and other industrial networks require compatible optional communication equipment.

The GA500 Safe Torque Off circuit is rated SIL3 under IEC 62061 and PLe under ISO 13849-1 when properly incorporated into a validated safety system. STO prevents motor torque but does not isolate the drive from the incoming single-phase power supply.

Technical Specifications

ManufacturerYaskawa
Complete ModelGA50UB010ABA
SeriesGA500
Input Supply200–240 VAC, Single Phase
Motor OutputThree-Phase Motor Control
Normal Duty Rating3 HP / 2.2 kW, 9.6 A
Heavy Duty Rating2 HP / 1.5 kW, 8.0 A
EnclosureIP20 Protected Chassis
Embedded CommunicationRS-485, MEMOBUS/Modbus RTU
Braking TransistorBuilt In

Application Engineering

Typical uses include small conveyors, workshop machinery, pumps, fans, packaging equipment, mixers and auxiliary automation systems. For single-phase installations, check the available branch-circuit capacity, voltage stability and upstream protection. The drive input current should be used when sizing the supply circuit.

The built-in braking transistor supports a separately selected external braking resistor. The resistor value and thermal capacity must match the braking energy and duty cycle. It is not included within the standard IP20 drive.

Installation and Commissioning Notes

Install the unit in a suitable control cabinet with adequate ventilation and protection from conductive contamination. Observe applicable derating requirements for temperature, altitude, carrier frequency and mounting arrangement. Separate power cables from low-level control and communication wiring and apply correct grounding practices.

During commissioning, confirm motor rotation, frequency limits, acceleration and deceleration time, fault behavior, STO operation and controller commands before connecting the machine to normal production.

Replacement Checklist

  • Confirm the complete GA50UB010ABA model code.
  • Verify 200–240 VAC single-phase input power.
  • Confirm that the motor is a compatible three-phase motor.
  • Select 9.6 A ND or 8 A HD operation.
  • Check upstream circuit capacity and protection.
  • Back up parameters and terminal assignments.
  • Verify STO, communication and braking components.

Related GA500 Models

GA50UB006ABA provides 6 A Normal Duty and 5 A Heavy Duty output. GA50UB012ABA provides 12.2 A Normal Duty and 11 A Heavy Duty output. GA50U2010ABA has similar output ratings but uses a three-phase input supply.

Inquiry and Supply Notes

Provide the available supply voltage and phase, complete drive nameplate, motor nameplate and application details with the inquiry. Confirm communication options, braking components, price and delivery time before ordering.

Send your message to this supplier
Send Now

Yaskawa GA50UB010ABA GA500 VFD 240V 1-Phase Input 3HP 9.6A IP20

Ask Latest Price
Model Number :
GA50UB010ABA
Enclosure Rating :
IP20 Protected Chassis
Payment Terms :
D/A, D/P, T/T, Western Union, MoneyGram,
Heavy Duty Power :
2 HP / 1.5 kW
Price :
USD 310/Unit
Packaging Details :
original packing
Contact Supplier
Yaskawa GA50UB010ABA GA500 VFD 240V 1-Phase Input 3HP 9.6A IP20

Dengfeng (XinXing) Trading Co., Limited

Site Member
1 Years
guangdong
Since 2024
Business Type :
Distributor/Wholesaler, Agent, Exporter, Trading Company, Seller
Total Annual :
1000000-1500000
Employee Number :
10~25
Certification Level :
Site Member
Contact Supplier
Submit Requirement