Corrosive Resistant Fog Salt Spray Test Chamber
Corrosion Tester For Stainless Steel
ASTM ISO EN Corrosive Resistant Salt Spray Fog Test Chamber Corrosion Tester for Stainless Steel
Product Features
- Constructed with imported PVC board for strong structure, deformation resistance, and high temperature acid/alkali resistance
- Automatic/manual water filling system with water level warning display
- Precision glass nozzle ensures uniform fog diffusion without crystal salt blocking
- Integrated control instrument for easy operation and clear visibility
- Double overtemperature protection and water level warning for safe operation
- Imported temperature controller with digital display, PID control, ±1℃ accuracy, and 999-hour maximum setting time
- Direct steam heating for rapid, uniform temperature increase and reduced standby time
- Spray tower with conical dispersion device for guided fog distribution and adjustable fog amount
- Pressure drum heating and humidification according to Henry's law
- Pneumatic cylinder automatic cover operation for large-scale machines
- Automatic defogging device for clear sample observation after testing
Compliance Standards
- GB/T 10125-1997 salt spray test
- GB/T 2423.17-1993 salt spray test
- GB/T 2423.18-2000 salt spray test
- GB.10587-89 salt spray test
- IEC68-2-11 salt spray test
- IEC68-2-52 1996 salt spray test
- ASTM.B117-97 salt spray test
- JIS H8502 salt spray test
- CNS.4158 salt spray test
- CNS.4159 CASS Accelerated acetic acid copper salt spray test
- GB/T 12967.3-91 CASS Accelerated acetic acid copper salt spray test
Technical Specifications
| Model | ZL-6001B (108L) | ZL-6001B (270L) | ZL-6001B (600L) |
| Inside Box Size (cm) | 60x45x40 | 90x60x50 | 160x100x50 |
| Outside Box Size (cm) | 107x60x118 | 141x88x128 | 210x130x140 |
| Testing Room Temperature | Salt test (NSS ACSS) 35℃±1℃ / Corrosion Test (CASS) 50℃±1℃ |
| Pressure Barrel Temperature | Salt test (NSS ACSS) 47℃±1℃ / Corrosion Test (CASS) 63℃±1℃ |
| Brine Temperature | 35℃±1℃ / 50℃±1℃ |
| Testing Room Capacity | 108L | 270L | 600L |
| Brine Tank Capacity | 15L | 25L | 50L |
| Salt Concentration | 5% sodium chloride or 5% sodium chloride with 0.26g per liter of copper chloride (CuCl₂·2H₂O) |
| Air Pressure | 1.00±0.01kgf/cm² |
| Spray Volume | 1.0~2.0ml/80cm²/h (16-hour minimum operation average) |
| Testing Room Relative Humidity | 85% above |
| PH | 6.5~7.2 / 3.0~3.2 |
| Spray Form | Programmable spray (continuous and intermittent) |
| Power | AC220V 1Φ 10A | AC220V 1Φ 15A | AC220V 1Φ 20A |