The B&R 8V1016.50-2 is a compact ACOPOS servo drive designed for operation from either single-phase or three-phase 110 to 230 VAC mains. It provides 3.6 A continuous motor current, 12 A peak current and a nominal motor power rating of 0.7 kW.
Its flexible mains connection makes it suitable for compact machinery and lower-voltage motion-control installations. The drive incorporates a line filter, braking resistor and electronic restart inhibit while retaining the modular ACOPOS plug-in interface concept.
| Manufacturer | B&R Industrial Automation |
| Complete Model | 8V1016.50-2 |
| Product Family | ACOPOS |
| Product Type | Servo Drive |
| Mains Input | 3-phase 110-230 VAC ±10% or 1-phase 110-230 VAC ±10% |
| Supply Frequency | 50/60 Hz ±4% |
| Maximum Installed Load | 2.1 kVA |
| Continuous Current | 3.6 A |
| Peak Current | 12 A |
| Nominal Motor Power | 0.7 kW |
| Plug-In Module Slots | 3 |
| Switching Frequencies | 5 / 10 / 20 kHz |
| Maximum Motor Cable Length | 15 m |
| Protection Class | IP20 |
| Dimensions | 58.5 * 257 * 220 mm |
| Approximate Weight | 2.5 kg |
The drive can be connected to either a suitable single-phase or three-phase supply within its specified voltage range. The three plug-in module slots support application-specific communication, encoder and I/O functions. Their exact part numbers and slot arrangement must be recorded from the original unit.
Confirm the complete number 8V1016.50-2. The “.50" version must not be confused with other 8V1016 voltage or hardware versions. Verify the mains supply, connected motor, feedback interface, communication module, slot configuration and machine project before ordering.
The motor holding brake output is intended to control a compatible holding brake. A motor holding brake is generally used for static holding and should not be treated as a normal dynamic service brake or a personnel-safety device.
Provide the complete drive nameplate, supply voltage, motor model, encoder type, installed plug-in modules and Automation Studio project information for cross-checking. Confirm separately whether connector sets, shield components or interface modules are required.