The B&R 8BVI0055HWD0.000-1 is a wall-mounted ACOPOSmulti dual-axis inverter module. It integrates two independent motor inverter outputs in one compact module, making it suitable for coordinated multi-axis machinery and control cabinets where installation space and shared DC-bus architecture are important.
Each motor connection provides 7.6 A continuous current, 18.9 A peak current and up to 5.5 kW continuous power. The module operates from the ACOPOSmulti backplane with a nominal 750 VDC bus and provides two slots for compatible ACOPOSmulti plug-in modules.
| Manufacturer | B&R Industrial Automation |
| Complete Model | 8BVI0055HWD0.000-1 |
| Product Family | ACOPOSmulti |
| Module Type | Dual-Axis Inverter Module |
| Motor Connections | 2 |
| Continuous Current per Axis | 7.6 A |
| Peak Current per Axis | 18.9 A |
| Continuous Power per Axis | 5.5 kW |
| Nominal DC Bus Voltage | 750 VDC |
| Switching Frequencies | 5 / 10 / 20 kHz |
| Plug-In Module Slots | 2 |
| Mounting | Wall mounting |
| Protection Class | IP20 |
| Dimensions | 53 * 317 * 263 mm |
| Approximate Weight | 2.9 kg |
The two motor outputs are independently controlled but share the ACOPOSmulti power and backplane environment. Motor cables, feedback interfaces, holding brakes and temperature sensors must be assigned to the correct axis. The two plug-in module positions must also match the original encoder and communication requirements.
Confirm the full model 8BVI0055HWD0.000-1. Similar ACOPOSmulti modules may differ in current rating, number of axes, cooling method, mounting arrangement, feedback hardware and integrated safety functions.
Before replacement, record the module position, backplane arrangement, plug-in modules, motor assignments, feedback connections and controller parameters for both axes. A module with a similar current rating should not be treated as automatically interchangeable.
For accurate identification, provide photographs of the complete nameplate, the front interface positions, adjacent ACOPOSmulti modules, both connected motor models and the machine project information. Confirm separately whether terminal blocks, shield components or plug-in modules are required.