Amaxpower OPzS Tubular Battery 2V 500Ah Deep Cycle Solar Gel Battery (2V 500Ah)
opzs batteries 2V 500Ah tubular deep cycle gel solar battery flooded lead acid battery for security system
Founded in 2005, Amaxpower is focusing on manufacturing high quality standard VRLA AGM battery, GEL battery and OPzS tubular battery. Based on battery technology innovation and deep understanding of customer demand,we are to be the most reliable supplier of battery power, to serve the telecom, solar power, wind power, smart grid etc strategic industry.
OPzS series is traditional tubular flood lead acid batteries. OPzS series provide excellent deep cycle life as well as extra-long float life, and recovery performance because of the tubular positive plate and flood electrolyte. OPzS series is mainly designed for solar energy storage, telecommunication, emergency power.etc.
OPzS series of 2V AGM deep cycle batteries are recognized as the most reliable and high quality battery system in the industry. They are designed with advanced patented GEL technology, Long service life designed with 10-15 years, 50% DOD 1200 Cycles, the batteries comply to the most popular international standards, such as IEC60896-21/22, BS6290-4, Eurobat Guide.
OPzS Series Flooded Tubular OPzS Lead Acid Battery 2VDC
Voltage: 2V
Capacity: 2V200Ah~2V3000Ah
Designed floating service life: >20 years @ 25 °C/77 °F.
Cyclic usage: 80% DOD, >2000cycles
Rate Voltage | 2V(Single cell) | |
Nominal Capacity | 500Ah @10 hour-rate | |
Dimension | Length | 166±1mm (6.45 inches) |
Width | 206±1mm (8.11 inches) | |
Container Height | 471±2mm (18.54 inches) | |
Total Height | 525±2mm (20.67 inches) | |
Weight | Approx. 36kg (79.37lbs) | |
Container Material | ABS | |
Reference Capacity (25°C) | 20hr (26.25A) | 525Ah |
10hr (50A) | 500Ah | |
5hr (85A) | 425Ah | |
1hr (316A) | 316Ah | |
Max. Discharge Current | 2000A (5S) | |
Internal Resistance (25°C) | Approx. 0.35mΩ | |
Cycle Use Voltage |
Initial Charging Current: Less than 100A Voltage: 2.37-2.4V @ 25°C (77°F) |
|
Float Charging Voltage | 2.25-2.3V @ 25°C (77°F) | |
Operating Temperature Range | Discharge | -15~50°C |
Charge | 0~40°C | |
Storage | -15~50°C | |
Nominal Operating Temperature Range | 25°C±3°C (77±5°F) | |
Capacity affected by Temperature (20 hour rate) | 40°C (104°F) | 105% |
25°C (77°F) | 100% | |
0°C (32°F) | 89% | |
-15°C (5°F) | 79% | |
Self-Discharge | Less than 3% at 25°C (77°F) per month |
Telecom, Electric Utilities, Control Equipments, Security Systems, Medical Equipments, UPS systems, Railroad Utilities, Photovoltaic Systems, Renewable Energy System and so on.