Hamamatsu 150KV X-Ray Source L12161-07 Integrated HV Power Supply 3 Focus Modes Industrial X-Ray CT
HAMAMATSU 150 kV MICROFOCUS X-RAY SOURCE L12161-07
FEATURES
- Focal spot size: 5 μm (at 4 W) - The sealed type X-ray tube offers sharp and clear X-ray images even at high magnification
- External control is realized via the RS - 232C interface
- High power: Maximum output 75 W
- High speed ramping-up - Faster than conventional 150 kV microfocus X-ray sources by up to 3 times
- No high voltage cable connection required - High voltage power supply is integrated
APPLICATIONS
- Non-destructive inspection
- X-ray CT
Applicable objects
- Printed circuit board
- Semiconductor device
- Electronic component
- Ceramic
- Plastic component
- Die casting
- Metal component
SPECIFICATIONS
GENERAL
| Parameter | Description/Value | Unit |
| X-ray tube voltage setting range | 0 to 150 | kV |
| X-ray tube current setting range | 0 to 500 | mA |
| X-ray tube voltage operational range 1 | 40 to 150 | kV |
| X-ray tube current operational range 1 | 10 to 500 | mA |
| Maximum output | Small Focus Mode: 10 W Middle Focus Mode: 30 W Large Focus Mode: 75 W | W |
| X-ray focal spot size (Nominal value) | Small Focus Mode: 7 (5 mm at 4 W) Middle Focus Mode: 20 Large Focus Mode: 50 | mm |
| X-ray beam angle 2 | Approx. 43 | degree |
| Focus to object distance (FOD) | Approx. 17 | mm |
| Rated output | Continuous rating | -- |
| Communication method | Interface: RS-232C (9-pin D-sub connector) | -- |
X-RAY TUBE UNIT
| Parameter | Description/Value | Unit |
| X-ray output window material / Thickness | Beryllium / 0.2 | mm |
| Target material | Tungsten | -- |
| Operating ambient temperature | +10 to +40 | °C |
| Storage ambient temperature | 0 to +50 | °C |
| Operating and storage humidity | 20 to 85 (No condensation) | % |
| Weight | Approx. 13.5 | kg |
X-RAY CONTROL UNIT
| Parameter | Description / Value | Unit |
| Input voltage (AC) | Single phase 100 to 240 (50 Hz / 60 Hz) | V |
| Power consumption | Less than 220 | W |
| Operating ambient temperature | +10 to +40 | °C |
| Storage ambient temperature | 0 to +50 | °C |
| Operating and storage humidity | 20 to 85 (No condensation) | % |
| Weight 3 | Approx. 6 | kg |
REGULATION AND STANDARDS
| Parameter | Description | Unit |
| RoHS directive | EN 50581 Category 9 | -- |
| EMC | IEC/EN 61326-1 Emission limits: CISPR 11 Group 1 Class A Immunity requirements: Table 2 | -- |
| Safety | IEC/EN 61010-1 | -- |
CONTROL SOFTWARE 4
| Parameter | Description | Unit |
| Applicable PC | PC / AT compatible | -- |
| Applicable OS | Windows® XP, 7 | -- |
| Interface | RS-232C interface | -- |
NOTE:
1. See the graph of the X-ray tube voltage / current operation range.
2. Reference value: With 50% of maximum X-ray emission.
3. This weight includes the accessories of approx. 1.5 kg.
4. The control software is provided as sample software for the purpose of MFX operation. The performance of the software is not guaranteed.