Model
|
THV-408(A~F)
|
THV-1000(A~F)
|
THV-1500(A~F)
|
|
Internal Dimension
W*H*D(mm)
|
600*850*800
|
1000*1000*1000
|
1500*1500*1500
|
|
External dimension
W*H*D (mm)
|
850*1950*2100
|
1300*2200*2400
|
1800*2400*3000
|
|
Temperature Range
|
Low temperature: (A: 25℃; B:0℃; C:-20℃; D: -40℃; E: -60℃; F:-70℃)
High temperature: 100℃ (150℃)
|
|
Humidity Range
|
20%~98%R.H.(10%-98% R.H. / 5%-98% R.H. is a special optional condition, need Dehumidifier)
|
|
Indication Resolution/
Distribution uniformity
of temperature and humidity
|
0.1degree C; 0.1% R.H/±2.0degree C; ±3.0% R.H.
|
|
Control Accuracy of
temperature and humidity
|
±0.5degree C; ±2.5% R.H.
|
|
Temperature Rising/
Falling Velocity
|
Temperature rising approx. 0.1~3.0degree C/min ;
temperature falling approx. 0.1~1.0degree C/min;
( Faster temperature rate is optional)
|
|
Internal and External Material
|
Material of the inner box is SUS 304# stainless steel,of the outer box is stainless steel or SEE cold-rolled steel with paint coated.
|
|
Insulation Material
|
Resistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials
|
|
Cooling System
|
Wind cooling or water cooling; single segment compressor for -40℃, double segment compressor for -70℃
|
|
Protection Devices
|
Fuse-free switch, overloading protection switch for compressor, high and low voltage coolant protection switch, over-humidity and over-temperature protection switch, fuses, fault warning system, water short storage warning protection
|
|
Optional Accessories
|
Inner door with operation hole(Optional) , Recorder(optional), Water Purifier, Dehumidifier
|