HDT Vicat Tester - Heat Deflection & Vicat Softening Point Instrument
This advanced Thermal Deformation & Vicat Softening Point Tester features PLC programmable temperature control with computer display operation. Designed for exceptional accuracy and stable performance, the system provides real-time monitoring of test temperature and deformation values throughout the testing cycle. Automatic heating termination and comprehensive test reporting with graphical curve output make this instrument essential for quality control in inspection authorities, academic institutions, and manufacturing enterprises.
Test Method Definitions
Thermal Deformation Temperature Test: Determines the temperature at which a standard specimen deflects by a specified amount under bending load, achieving designated nominal surface stress in compliance with international standards. This method is crucial for plastic quality control and material R&D.
Vicat Softening Point Temperature Test: Measures the temperature at which a standard indenter penetrates 1 mm into the specimen surface under defined loading. Used to differentiate softening characteristics across various thermoplastic materials.
Key Features
- Specimen frame lifting mechanism for easy sample handling
- Measures thermal deformation and Vicat softening point temperatures
- Compatible with non-metallic materials including plastics, rubber, nylon, and electrical insulation materials
- Real-time temperature and deformation monitoring
- Automatic heating termination upon test completion
- Test report and graphical curve output capabilities
Compliance Standards
This testing instrument complies with comprehensive domestic and international standards including GB/T1633, GB/T1634, ISO75, ISO306, ASTM D648, ASTM D1525, and ISO 2507. Conformity ensures traceability and credibility of test results, meeting thermal performance evaluation requirements for laboratories, manufacturing facilities, and certification organizations.
Technical Specifications - Model XRW-300F
| Parameter |
Specification |
| Testing Stations |
3 stations (simultaneous testing of 3 samples) |
| Automation |
Automatic sample movement capability |
| Cooling System |
Air cooling above 150°C, water or natural cooling below 150°C |
| Deformation Measurement |
High precision digital display dial gauge |
| Heating Rates |
50°C/h, 120°C/h |
| Maximum Temperature Deviation |
±0.5°C |
| Deformation Deviation |
0.01mm |
| Vicat Loads |
10N ± 0.2N, 50N ± 1N |
| Fiber Stress |
0.455 MPa and 1.82 MPa |
| Temperature Control Range |
Room temperature ~ 300°C |
| Deformation Measuring Range |
0 ~ 10mm |
| Sample Frame Number |
3 |
| Test Span |
60~120mm |
| Heating Power |
6KW |
| Power Supply |
220V 50Hz |
| Display |
Color touch screen |
| Type and Display |
Vertical type using computer control system |
Standard Configuration
- Main frame: 1 set
- Electric cabinet: 1 set
- Specimen holder: 3 sets
- Vicat indenter: 3 sets
- Heat deflection indenter: 3 sets
- Displacement sensor: 3 sets
- Power line: 2 sets
- Connecting line: 2 sets
- Operation manual: 1 set
- Certificate: 1 set
- Packing list: 1 set