Specifications
Voltage - Supply :
30V
Description :
Position, Proximity, Speed (Modules) RoHS
Mfr. Part # :
FF6-20-DC-QD05
Model Number :
FF6-20-DC-QD05
Description

Honeywell FF6 Series Non-Contact Safety Switches

The Honeywell FF6 Series are magnetically actuated, non-contact safety limit switches designed for machine guarding applications. They monitor guard positions and provide input to safety relays. Their slim, rectangular design is ideal for space-constrained installations. The non-contact operation and flexible installation options, including head-on, slide-by, or rotational approach, minimize setup and accommodate potential guard misalignment. With IP67 sealing and global certifications (CE, UKCA, UL), these switches are suitable for wet, dusty, and international environments.

Product Attributes

  • Brand: Honeywell
  • Product Line: FF6 Series
  • Type: Non-Contact Safety Limit Switches
  • Actuation: Magnetically Actuated
  • Housing Material: ABS plastic or 316 stainless steel
  • Certifications: CE, UKCA, UL 508
  • Environmental Sealing: IP67

Technical Specifications

Catalog Listing Contact Configuration Housing Material Cable Length / Connector Application Certifications Dimensions (Switch/Actuator) Operating Temperature Sensing Distance (Safety)
FF6-10-AC-03 1NC ABS Plastic 3 m [9.8 ft] Pre-wired AC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-10-AC-06 1NC ABS Plastic 6 m [19.7 ft] Pre-wired AC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-10-AC-QD05 1NC ABS Plastic M12 integral connector, 5 m [16.4 ft] mating cable AC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-10-DC-03 1NC ABS Plastic 3 m [9.8 ft] Pre-wired DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-10-DC-06 1NC ABS Plastic 6 m [19.7 ft] Pre-wired DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-10-DC-QD05 1NC ABS Plastic M12 integral connector, 5 m [16.4 ft] mating cable DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-11-AC-03 1NC/1NO ABS Plastic 3 m [9.8 ft] Pre-wired AC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF (Safety)
11 mm [0.43 in] OFF / 21 mm [0.83 in] ON (Auxiliary)
FF6-11-AC-06 1NC/1NO ABS Plastic 6 m [19.7 ft] Pre-wired AC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF (Safety)
11 mm [0.43 in] OFF / 21 mm [0.83 in] ON (Auxiliary)
FF6-11-AC-QD05 1NC/1NO ABS Plastic M12 integral connector, 5 m [16.4 ft] mating cable AC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF (Safety)
11 mm [0.43 in] OFF / 21 mm [0.83 in] ON (Auxiliary)
FF6-11-DC-03 1NC/1NO ABS Plastic 3 m [9.8 ft] Pre-wired DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF (Safety)
11 mm [0.43 in] OFF / 21 mm [0.83 in] ON (Auxiliary)
FF6-11-DC-06 1NC/1NO ABS Plastic 6 m [19.7 ft] Pre-wired DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF (Safety)
11 mm [0.43 in] OFF / 21 mm [0.83 in] ON (Auxiliary)
FF6-11-DC-QD05 1NC/1NO ABS Plastic M12 integral connector, 5 m [16.4 ft] mating cable DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF (Safety)
11 mm [0.43 in] OFF / 21 mm [0.83 in] ON (Auxiliary)
FF6-20-AC-03 2NC ABS Plastic 3 m [9.8 ft] Pre-wired AC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-20-AC-06 2NC ABS Plastic 6 m [19.7 ft] Pre-wired AC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-20-AC-QD05 2NC ABS Plastic M12 integral connector, 5 m [16.4 ft] mating cable AC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-20-DC-03 2NC ABS Plastic 3 m [9.8 ft] Pre-wired DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-20-DC-06 2NC ABS Plastic 6 m [19.7 ft] Pre-wired DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-20-DC-QD05 2NC ABS Plastic M12 integral connector, 5 m [16.4 ft] mating cable DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF
FF6-21-AC-QD05 2NC/1NO ABS Plastic M12 6-pin integral connector, 5 m [16.4 ft] mating cable AC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF (Safety)
11 mm [0.43 in] OFF / 21 mm [0.83 in] ON (Auxiliary)
FF6-21-DC-03 2NC/1NO ABS Plastic 3 m [9.8 ft] Pre-wired DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF (Safety)
11 mm [0.43 in] OFF / 21 mm [0.83 in] ON (Auxiliary)
FF6-21-DC-06 2NC/1NO ABS Plastic 6 m [19.7 ft] Pre-wired DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF (Safety)
11 mm [0.43 in] OFF / 21 mm [0.83 in] ON (Auxiliary)
FF6-21-DC-QD05 2NC/1NO ABS Plastic M12 6-pin integral connector, 5 m [16.4 ft] mating cable DC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF (Safety)
11 mm [0.43 in] OFF / 21 mm [0.83 in] ON (Auxiliary)
FF6-10-AC-03-SS 1NC 316 Stainless Steel 3 m [9.8 ft] Pre-wired AC cULus/UL 508, CE, UKCA 19.0 mm x 19.0 mm x 82.5 mm [0.75 in x 0.75 in x 3.25 in] -25C to 55C [-13F to 131F] 10 mm [0.39 in] ON / 28 mm [1.10 in] OFF

Potential Applications

  • Equipment and machinery guards
  • Can forming and filling (aluminum, plastic, and steel)
  • Packaging equipment
  • Pick and place assembly equipment
  • Plastic molding equipment
  • Printing machinery
  • Semiconductor equipment
  • Textile machinery
  • Woodworking equipment

2411261506_Honeywell-FF6-20-DC-QD05_C17652922.pdf

Send your message to this supplier
Send Now

Honeywell FF6 20 DC QD05 Non Contact Safety Limit Switch Magnetically Actuated for Industrial Safety

Ask Latest Price
Voltage - Supply :
30V
Description :
Position, Proximity, Speed (Modules) RoHS
Mfr. Part # :
FF6-20-DC-QD05
Model Number :
FF6-20-DC-QD05
Contact Supplier
Honeywell FF6 20 DC QD05 Non Contact Safety Limit Switch Magnetically Actuated for Industrial Safety

Changsha Purple Horn E-Commerce Co., Ltd.

Verified Supplier
1 Years
hunan, changsha
Since 2009
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Importer
Employee Number :
300~500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement