High Output VRS sensors are designed for applications requiring higher output voltages, performing optimally at low to medium speeds with medium to high impedance loads. They are passive, self-powered devices that convert actuator speed directly into output frequency without external voltage. Front-End Sealed versions are available for harsh environments. These sensors are simple, rugged, and have no moving parts, making them adaptable to various configurations and ideal for precise speed sensing.
| Model | Housing Diameter | Output Voltage (Min Vp-p) | Coil Resistance | Gear Pitch Range | Operating Temp. Range | Termination | Weight |
| 3030AN Series | 5/8 in (M16) | 190 | 910 Ohm to 1200 Ohm | 24 DP (module 1.06) or coarser | -55 C to 120 C | MS3106 connector | 70 g to 128 g |
| 3030S Series | 5/8 in (M16) | 190 | 910 Ohm to 1200 Ohm | 24 DP (module 1.06) or coarser | -55 C to 120 C | 20 AWG Teflon- insulated Leads | 70 g to 84 g |
| 3030H Series | 5/8 in (M16) | 190 | 910 Ohm to 1200 Ohm | 24 DP (module 1.06) or coarser | -55 C to 120 C | 20 AWG Teflon- insulated leads | 140 g |
| 3030A Series | 5/8 in (M16) | 190 | 910 Ohm to 1200 Ohm | 24 DP (module 1.06) or coarser | -55 C to 120 C | MS3106 connector | 70 g to 84 g |
| MA230SAN Series | 5/8 in (M16) | 175 | 910 to 1200 Ohm | 24 DP (module 1.06) | -55 C to 150 C | MS3106 connector | 70 g to 98 g |
| MA240SAN Series | 5/8 in (M16) | 60 | 120 to 162 Ohm | 12 DP (module 2.11) | -55 C to 150 C | MS3106 connector | 70 g to 98 g |
| 3025A Series | 3/8 in (M12) | 55 | 275 Ohm to 330 Ohm | 26 DP (module 0.98) or coarser | -40 C to 107 C | 24 AWG, vinyl-insulated leads | 28 g to 42 g |
| 3025S Series | 3/8 in (M12) | 55 | 275 Ohm to 330 Ohm | 26 DP (module 0.98) or coarser | -40 C to 107 C | 24 AWG, vinyl-insulated leads | 28 g |