Measurement Principle: Imported microfluidic thermal conductivity method
Measurement Principle/Range:



| Parameter | Value |
|---|---|
| Accuracy | ±1.5%F.S |
| Resolution | 0.01% |
| Repeatability | ±1% |
| Stability | ±1%F.S /7d |
| Response Time | T90≤10 S |
| Storage Interval | 1S-99 min |
| Number of Stored Points | Millions+ |
| Instrument Lifespan | 6 years for the whole unit, 2-3 years for the sensor (under proper operating conditions) |
| Operating Voltage | 24VDC, 1A |
| Total Power Consumption | ≤10W |
| Digital Signal | Standard RS485/RS232 communication ports, enabling two-way communication with computers |
| Analog Output | 4~20mA standard output signal, load resistance less than 500 ohms (0~10V optional) |
| Installation Method | Embedded installation |
| Dimensions | Analyzer: 150mm(w) × 150mm(h) × 200 mm(d) Secondary Meter: 160mm(w)×80mm(h)×170mm(d) (dimensions can be customized) |
| Opening Size | Analyzer: 136mm(w)×136mm(h) Secondary Meter: 150mm (w)×75mm(h) |
| Explosion-proof Mark | Ex ib IIC T6 Gb |
| Inlet and Outlet Ports | Φ6 hose (can be customized according to customer requirements) |
| Total Weight | 1.5kg |
| Ambient Temperature | –25℃~+55℃ |
| Ambient Humidity | ≤90%RH |
| Inlet Pressure | 0.05 MPa≤Inlet Pressure≤0.25Mpa |
| Sample Gas Flow Rate | (400±50)ml/min |
| Sample Gas Requirements | Dust-free, water-free, oil-free |
Widely used in industrial production processes such as chemical engineering, metallurgy, coal mining, environmental protection, and biofermentation for online detection and analysis of hydrogen content in intrinsically safe and non-explosion-proof applications.