6kW Single Phase Hybrid Inverter with IP65 Protection
This hybrid inverter series is engineered to simultaneously support photovoltaic (PV) and energy storage systems. It combines grid-tied and off-grid operation with bidirectional power control and intelligent energy management for fully autonomous power dispatch. Featuring a modern design that integrates seamlessly into smart home environments, it provides an ideal power solution for residential applications.
Compatible with a wide range of battery types and optimized for use with our dedicated battery series, this inverter supports multiple charge and discharge power settings to ensure safe, stable, and reliable residential power supply.
Key Features
Safety Features
- Intelligent AI-DC Arc fault protection
- Supports 2 times overload for short durations
- IP65 protection rating
Flexible Operation
- Compatible with diesel generators
- AC coupling for retrofitting existing solar systems
- Maximum 10 units parallel operation for on/off-grid use
- Supports multiple battery parallel connections
Smart Management
- 4ms backup power switching
- Colored LCD touchscreen for intuitive setup and real-time monitoring
- Supports programming of 6 time periods for battery charging/discharging
High Efficiency Performance
- Supports 1.6 times DC overloading
- 180A charge and discharge current
- 97.6% maximum conversion efficiency and 95% maximum charging efficiency
Technical Specifications
Model Numbers
CH-LVEH1P6K-EU-G1, CH-LVEH1P6K-BR-G1
| Battery Input Data |
| Battery Type |
Lead-acid/Li-Ion |
| Battery Voltage Range (V) |
40~60 |
| Max. Charging Current (A) |
135 |
| Max. Discharging Current (A) |
135 |
| Charging Strategy for Li-ion Battery |
Self-adaption to BMS |
| Number of Battery Input |
1 |
| PV String Input Data |
| Max. PV Input Power (W) |
9600 |
| Max. PV Input Voltage (V) |
500 |
| Start-up Voltage (V) |
120 |
| MPPT Voltage Range (V) |
120~425 |
| Rated PV Input Voltage (V) |
370 |
| Max Operating PV Input Current (A) |
20+20 |
| Max. Input Short-Circuit Current (A) |
23 |
| No. of MPP Tracker/No. of Strings MPP Tracker |
2/1+1 |
| AC Input/Output Data |
| Rated AC Input/Output Active Power (W) |
6000 |
| Max. AC Input/Output Apparent Power (VA)* |
6600 |
| Rated AC Input/Output Current (A) |
27.3/26.1 |
| Max. AC Input/Output Current (A)* |
30/28.7 |
| Max. Continuous AC Passthrough (grid to load) (A) |
54 |
| Peak Power (off-grid) (W) |
2 times of rated power for 10s |
| Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
| Rated Input/Output Voltage/Range (V) |
220/230 0.85Un-1.1Un |
| Rated Input/Output Grid Frequency/Range (Hz) |
50/45-55, 60/55-65 |
| Grid Connection Form |
L+N+PE |
| Total Current Harmonic Distortion THDi |
<2% (of nominal power) |
| DC Injection Current |
<0.5% In |
| Efficiency |
| Max. Efficiency |
97.60% |
| Euro Efficiency |
96.50% |
| MPPT Efficiency |
99% |
| Equipment Protection |
| Integrated Protection |
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection |
| Surge Protection Level |
TYPE II (DC), TYPE II (AC) |
| Interface |
| Communication Interface |
RS485/CAN |
| Monitor Mode |
WIFI |
| General Data |
| Operating Temperature Range (°C) |
-40 to +60 |
| Permissible Ambient Humidity |
0-100% |
| Permissible Altitude (m) |
3000 |
| Ingress Protection (IP) Rating |
IP65 |
| Inverter Topology |
Non-Isolated |
| Over Voltage Category |
OVC II (DC), OVC III (AC) |
| Cabinet Size (WxHxD mm) |
330*563*223 |
| Weight (kg) |
23.7 |
| Type of Cooling |
Natural cooling |
| Warranty |
5 Years/10 Years |
| Safety/EMC Standard |
IEC/EN 61000-6-1:2019, IEC/EN 62109-1:2010, IEC/EN 62109-2:2011, IEC 63027:2023 |
*It is only implemented under specific safety regulations and working conditions
The warranty period depends on the final installation site of the inverter. More information please refer to warranty policy.