8kW Single Phase Hybrid Inverter with IP65 Protection
This hybrid inverter series delivers advanced bidirectional power control for energy storage systems, seamlessly integrating photovoltaic and battery storage operations. Engineered for residential applications, it combines grid-tied and off-grid functionality with intelligent energy management for complete energy autonomy.
Compatible with diverse battery technologies including our dedicated battery series, this inverter supports multiple charge/discharge power configurations to ensure safe, stable, and reliable residential power supply.
Safety Features
- Intelligent AI-DC Arc fault protection
- Supports 2x overload capacity for short durations
- IP65 protection rating
Flexible Operation
- Compatible with diesel generators
- AC coupling for retrofitting existing solar systems
- Max. 10 units parallel operation for on/off-grid
- Supports multiple battery parallel connection
Smart Control
- 4ms backup power switching
- Color LCD touchscreen for setup & monitoring
- 6 programmable time periods for battery charging/discharging
High Efficiency
- Supports 1.6x DC overloading
- 180A charge and discharge current
- 97.6% maximum conversion efficiency
- 95% maximum charging efficiency
Technical Specifications
Model Numbers
CH-LVEH1P8K-EU-G1, CH-LVEH1P8K-BR-G1
Battery Input Data
| Battery Type |
Lead-acid/Li-Ion |
| Battery Voltage Range (V) |
40~60 |
| Max. Charging Current (A) |
180 |
| Max. Discharging Current (A) |
180 |
| Charging Strategy for Li-ion Battery |
Self-adaption to BMS |
| Number of Battery Input |
1 |
PV String Input Data
| Max. PV Input Power (W) |
12800 |
| Max. PV Input Voltage (V) |
500 |
| Start-up Voltage (V) |
120 |
| MPPT Voltage Range (V) |
120~425 |
| Rated PV Input Voltage (V) |
370 |
| Max Operating PV Input Current (A) |
20+20 |
| Max. Input Short-Circuit Current (A) |
23 |
| No. of MPP Tracker / No. of Strings MPP Tracker |
2/1+1 |
AC Input/Output Data
| Rated AC Input/Output Active Power (W) |
8000 |
| Max. AC Input/Output Apparent Power (VA)* |
8800 |
| Rated AC Input/Output Current (A) |
36.4/34.8 |
| Max. AC Input/Output Current (A)* |
40/38.3 |
| Max. Continuous AC Passthrough (grid to load) (A) |
54 |
| Peak Power (off-grid) (W) |
2 times of rated power for 10s |
| Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
| Rated Input/Output Voltage/Range (V) |
220/230 0.85Un-1.1Un |
| Rated Input/Output Grid Frequency/Range (Hz) |
50/45-55, 60/55-65 |
| Grid Connection Form |
L+N+PE |
| Total Current Harmonic Distortion THDi |
<2% (of nominal power) |
| DC Injection Current |
<0.5% In |
Efficiency
| Max. Efficiency |
97.60% |
| Euro Efficiency |
96.50% |
| MPPT Efficiency |
99% |
Equipment Protection
Integrated: DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge Protection Level
Surge Protection Level
TYPE II (DC), TYPE II (AC)
Interface
| Communication Interface |
RS485/CAN |
| Monitor Mode |
WIFI |
General Data
| Operating Temperature Range (°C) |
-40 to +60 |
| Permissible Ambient Humidity |
0-100% |
| Permissible Altitude (m) |
3000 |
| Ingress Protection (IP) Rating |
IP65 |
| Inverter Topology |
Non-Isolated |
| Over Voltage Category |
OVC II (DC), OVC III (AC) |
| Cabinet Size (WxHxD mm) |
330×563×223 |
| Weight (kg) |
24.9 |
| Type of Cooling |
Intelligent Air Cooling |
| Warranty |
5 Years / 10 Years |
The warranty period depends on the final installation site of inverter. More information please refer to warranty policy.
Safety/EMC Standard
IEC/EN 61000-6-1:2019, IEC/EN 62109-1:2010, IEC/EN 62109-2:2011, IEC 63027:2023
*It is only implemented under specific safety regulations and working conditions