Thermal Conductivity Device ASTM C518 ISO 8301 for Thermal Insulation Materials
Product Overview
The thermal conductivity measured by the high-temperature resistant material thermal conductivity tester refers to the amount of heat transferred per unit time along the heat flow direction through a unit area of the material under a unit temperature gradient.
Based on the fundamental principle of Fourier one-dimensional plate steady-state heat conduction, this device measures the amount of heat transferred longitudinally through the hot surface of the sample to the cold surface and then absorbed by the water flowing through the central calorimeter per unit time in a one-dimensional temperature field during steady-state operation.
Compliance Standards
ASTM C518: Standard test method for determining steady-state thermal conductivity using a heat flow meter
ISO 8301: Determination of adiabatic steady-state thermal resistance and related properties using the heat flow meter method
Technical Specifications
| Parameter |
Specification |
| Test Temperature |
Variable, 0~70℃ |
| Cooling System |
Self-developed high-precision low-temperature constant temperature water bath, temperature control accuracy ±0.001℃, integrated control by testing software |
| Temperature Measurement and Display Accuracy |
±0.01℃ |
| Programmable Data Points |
10 |
| Sample Size (L*W*H) mm |
300*300*50 (or 200*200*50), thickness 0~50mm automatically adjustable |
| Sample Pressure Automatic Adjustable Range |
0-1500N (16.5kPa) |
| Thermal Resistance Range |
0.05~5.0 m²*K/W |
| Thermal Conductivity Range |
0.002~0.5 W/m*K |
| Measurement Accuracy |
Within ±3%, accuracy within ±1% for measuring the US standard plate NIST 1450E |
| Repeatability |
1% |
Key Features
- Powder-coated outer casing for excellent appearance, high mechanical strength, corrosion resistance, and rust prevention
- High heating temperature capability up to 1200℃ with nine parallel silicon carbide rods ensuring temperature uniformity
- Short testing time: 8-12 hours typical, saving manpower, resources, and time
- Wide measurement range: 0.03-2.00 W/(m*K) for various refractory materials
- High-alumina fiber cotton construction for improved operating temperature, extended service life, reduced weight and size
- Capability to test multiple layers of specimens simultaneously
- Long service life with pressure-resistant, corrosion-resistant rubber tubing and anti-slip nuts for enhanced stability
- High safety factor with independent circuitry and water circulation design
- Excellent temperature stability with protective calorimeter design
- Advanced control system using Omron PLC and Schneider Electric solid-state switching devices
- Simple operation with detailed product manual and step-by-step guidance
- RS-232 standard serial communication for stable, reliable data acquisition
- User-friendly computer interface with automatic and manual control modes
- Comprehensive software capabilities including automatic data generation, storage, reporting, and curve analysis
Laboratory Environmental Requirements
- Power supply: 220V, 50HZ
- Test temperature: (23±2)℃
- Test humidity: (40~60)%RH
Instrument Set Includes
- One thermal conductivity tester main unit
- One set of testing software (including communication interface)
- One set of constant temperature water bath and its controller
- One computer
- One set of data cables