DC Main Control Board Aging Cabinet, DC~DC Series Power Supply Burning-in Test Stand



| Burn-in cabinet structure and Burn-in quantity planning |
Trolley size (mm) | L2050*W1250*H2050mm |
| Number of trolley layers | 4 layers, product area depth 400mm (6 Burn-in positions per layer) | |
| Trolley height | 175mm | |
| Trolley structure material | cold rolled sheet | |
| Load area heat dissipation mode | Top turbine exhaust fan top row type (easy to control the ambient temperature | |
| Layer insulation and anti-static method | Epoxy insulation board with heat dissipation holes on the surface | |
| Overall burn-in room structure | Adopt mobile Burn-in split cabinet; beautiful appearance and easy to move and combine | |
| Introduction to energy recovery module configuration, power of the tested power supply and Burn-in quantity |
Energy recovery module control mode | RS485 communication mode, upper computer uses RS232 communication mode |
| DC power supply capability | 10-100Vdc/1-30A/3kW (adjustable voltage and current) | |
| Electronic load module isolation mode | Electronic load module channel adopts photoelectric isolation (communication and power supply isolation) | |
| Electronic load carrying capacity | 8 channels 1-400Vdc/10A/150W(support QC3.0/PD3.1),4 channels 3-60VDC /40A/500W | |
| Number of installed electronic loads | 1. A single burn-in cabinet is configured with CP8104/48 sets 2. A single burn-in cabinet is configured with CP8512/24 sets | |
| Energy recovery module design architecture | No relay, long life design scheme (independent intellectual property rights) | |
| Number of burn-in products in the entire cabinet | 48 BMS controllers less than 3.2KW are aged in one cabinet | |
| Introduction of electric control and temperature control device for power Burn-in cabinet |
Connection mode | Customer specified interface; input port is pin socket |
| Panel function keys | Input AC voltage display, start switch, emergency stop switch | |
| Trolley power distribution and control mode | 380V three-phase five-wire distribution; Computer monitoring and automatic electric control | |
| Trolley power distribution | A single burn-in cabinet is 3000W*8/0.85≈23KW, and the measured power efficiency is calculated as 85% | |
| Control mode | The electric control includes manual/automatic switching, which is monitored by the computer in real time when burn-in. The electric control cabinet can extend the automatic switching function of AC voltage |
|
| Safety protection | Equipment grounding protection, leakage switch protection, smoke alarm automatic power-off protection, etc | |
| Introduction to the main functions of the system | Suitable for k DC main control board,BMS controller DC to DC series power supply burn-in test | |
| Free configuration of self-developed special monitoring software for power Burn-in, with independent intellectual property rights and no legal risks | ||
| Use programmable electronic load module to monitor output terminal voltage, current and power parameters | ||
| Aging special monitoring software enjoys lifetime free upgrade service, powerful scalability and saving equipment repeated investment | ||
| Burn-in parameters, time setting, ON/OFF sequence editing (test of the product being tested on and off), support for automatic voltage switching, load conversion and other functions can be programmed (Burn-in parameters can be automatically switched in a fixed time period) |
||
| The function of automatically turning off the power at the end of the Burn-in of the tested power supply is convenient for unattended | ||
| The computer automatically displays the quality of the tested power supply product, and multiple windows in the window are convenient for centralized management, which saves operators and improves production efficiency | ||
| The computer can store the Burn-in data report of the tested power supply, the process parameters of the tested power supply are easy to trace; in addition, it has barcode scanning and supports MES system uploa | ||
| RS232 to RS485 adopts photoelectric isolation converter to improve communication reliability and prevent lightning damage to equipment | ||
| Each computer can monitor 18 devices at the same time, (each serial port can connect to 63 slaves, and each computer supports up to 18 serial ports) | ||
| The power Burn-in monitoring software has a built-in help file, which is convenient for solving operation questions immediately | ||