New Energy Vehicle Electric Drive Controller (MCU) Typical Burn-in Tester
Advanced burn-in testing system designed specifically for New Energy Vehicle Electric Drive Controllers (MCU), ensuring reliability and performance validation through comprehensive environmental and electrical testing.
System Configuration & Specifications
| Category |
Project |
Content |
| System |
System structure |
1 control cabinet + 2 aging cabinets + 1 water temperature cabinet |
| Overall size |
6900*1600*2050mm |
| Total floor area |
6900*2500mm (Including operation area) |
| Total input voltage |
Three-phase five-wire system 380Vac (rated) |
| Total input current |
250A |
| Total input power |
150kW |
| Application ambient temperature |
0-40℃ |
| Application environment humidity |
0-95% |
| Fire protection requirements |
Materials meet UL 94V0 rating |
| Environmental requirements |
Materials comply with Rohs, WEEE requirements |
| Safety requirements |
Comply with IEC62368 international standard design requirements |
Burn-in Cabinet Specifications
| Parameter |
Specification |
| Burn-in bits/cabinet |
16 bits/cabinet |
| Burn-in product power |
20kW/bit |
| Burn-in product input voltage |
150-1000Vdc |
| Burn-in product input current |
50A/bit |
| Burn-in Product Load Category |
Inductive/Motor/AC Feedback Load |
| Burn-in product load current |
350A (inductor/motor)/40A (AC feedback load) |
| Auxiliary voltage of Burn-in products |
8-30Vdc |
| Auxiliary current of Burn-in products |
10A |
| Power Connector Type |
SB50 (HV+/HV-) |
| AC Connector Type |
PA350 (L1/L2/L3/N/PE) |
| Signal Connector Type |
24Pin 5566 |
| Constant temperature range |
Room temperature+5℃-60℃ |
| Input power |
320kW |
| Feedback power |
256kW |
| Volume size |
2100*1600*2050mm |
| Material |
Cold rolled sheet |
Water Temperature Cabinet Specifications
| Parameter |
Specification |
| Water temperature range |
Room temperature+5°C-60°C |
| Water temperature accuracy |
±5°C |
| Water temperature |
8 |
| Number of serial products/way |
4/way |
| Dissipated power/circuit |
4kW/way |
| Cooling method |
Chilled water or air cooling |
| Water pressure range |
0.05-0.2MPa |
| Flow range |
3-15L/min |
| Channel diameter |
3/4 inch |
| Volume size |
880*1000*1900mm |
Monitoring Software Capabilities
| Feature |
Specification |
| Display accuracy |
±(1%+0.2%FS) |
| Control precision |
±(1%+0.2%FS) |
| Bad way of reporting |
Audible alarm |
| Report format |
CSV format |