Burn-In Test For Large-Scale Energy Storage Converters Power Conversion System
Architecture diagram


Performance parameters

| System | System structure | 1 control cabinet + 6 two-way source load cabinets |
| Overall size | 5800*860*2050mm |
| Total floor area | 5800*1800mm(Including operation area) |
| Total input voltage | Three-phase five-wire system 220Vac (rated) |
| Total input current | 100A*6 |
| Total input power | 50kW*6 |
| Application ambient temperature | 0-40℃ |
| Application environment humidity | 0-95% |
| Fire protection requirements | Materials meet UL 94V0 rating |
| Environmental requirements | Materials comply with Rohs, WEEE requirements |
| Safety requirements | Comply with IEC62368 international standard design requirements |
| Burn-in cabinet | Units/Cabinet | 2 bits/cabinet |
| Burn-in product DC power | 150kW/bit |
| Burn-in product DC voltage | 150-800Vdc |
| Burn-in product DC current | 500A/bit |
| Burn-in product AC power | 150kW/bit |
| Burn-in products AC voltage | 220/380Vac/50Hz Three-phase five-wire |
| Burn-in product AC current | 300A/bit |
| AC Connector Type | PA350 (L1/ L2/ L3/N/PE) |
| DC Connector Type | DC bronze medal |
| Signal Connector Type | RJ45 (network port) |
| Input power | 300kW |
| Feedback power | 280kW |