200V 300A Charge 600A Discharge Battery Comprehensive Tester For Lithium Ion Battery Pack
Product Description
ACEY-BIT200-300A600A battery comprehensive tester is used for comprehensive performance testing of lithium-ion power battery packs for energy storage modules, electric vehicles, electric scooters, AGVs, and garden tools. It supports all series of batteries with CH+ / P+ / CH− / P− terminals and is suitable for testing both semi-finished and finished products in the production process. The main test items include battery open-circuit voltage, AC internal resistance, continuous charge and discharge current and voltage, charge and discharge over-current protection, short-circuit protection response time, over-current delay, and post-test voltage verification.
Test Items
- Voltage: Measures voltage twice—no-load voltage and post-test voltage (especially after short-circuit protection) to verify battery condition. Voltage range: 0–120 V.
- Internal Resistance: Measures AC internal resistance at 1000 Hz. Range: 0–4000 mΩ.
- Charge Over-current Protection Current: Verifies BMS protection against excessive charge current. If no protection is present, continuous charge current is applied. Range: 0–100 A.
- Continuous Charge Current: For batteries without charge over-current protection, the charge current is set to match the charger. Range: 0–100 A.
- Charge Voltage Monitoring: Monitors voltage limits during continuous charging to detect over-range conditions. Range: 0–120 V.
- Discharge Over-current Protection & Delay: Tests automatic protection when discharge current exceeds the set value. Range: 0–500 A, max power 60 kW. Supports step and fast test modes.
- Continuous Discharge Current: Verifies the battery’s ability to sustain normal operating discharge current. Range: 0–500 A.
- Discharge Voltage Monitoring: Monitors voltage limits during continuous discharge. Range: 0–120 V.
- Short-circuit Protection Time: Measures BMS response time during momentary short circuit. Typical requirement <1000 μs. Max short-circuit current resistance up to approx. 5000 A.
- Cell Voltage Monitoring: Dynamic monitoring of individual cell voltage during charge and discharge.
- Charge / Discharge Voltage Rise & Drop: Compares end-of-charge voltage with static voltage, and end-of-discharge voltage with initial voltage, to evaluate voltage rise and drop.
Main Technical Parameter
| Item |
Range |
Resolution |
Accuracy / Notes |
| Voltage |
0–120 V |
1 mV |
±0.1% RD + 0.1% FS |
| Internal Resistance |
0–2000 mΩ |
0.001 mΩ |
±0.1% RD + 0.1% FS |
| Charge Current |
0–100 A |
0.001 A |
±0.1% RD + 0.1% FS |
| Discharge Current |
0–500 A |
0.001 A |
±0.1% RD + 0.1% FS (500 A continuous at max voltage; higher current customizable) |
| Over-current Delay Time |
0–30 s |
1 ms |
±0.1% RD + 0.1% FS |
| Short-circuit Time |
0–2000 μs |
1 μs |
±0.1% RD + 0.1% FS |
| NTC |
0–100 kΩ |
0.001 kΩ |
— |
| R1 |
0–100 kΩ |
0.001 kΩ |
— |
| Operating Voltage |
AC 200–240 V |
— |
— |
| Max Charging Power |
12 kW |
— |
At maximum charge current |
| Max Discharging Power |
60 kW |
— |
At maximum discharge current |
| Surge Voltage |
<15 V |
— |
— |
Product Display