| MODEL | ASF4880U180-H | ASF48100U200-H | ||
| INVERTER OUTPUT | | | ||
| Rated Output Power | 8,000W | 10,000W | ||
| Max.Peak Power | 16,000W | 20,000W | ||
| Rated Output Voltage | 120Vac(single phase L+N+PE)/ 240Vac(split phase L1+L2+N+PE) | | ||
| Load Capacity of Motors | 5HP | 6HP | ||
| Rated AC Frequency | 50/60Hz | | ||
| Waveform | Pure Sine Wave | | ||
| Switch Time | 10ms(typical) | | ||
| Output Mode | Off-grid(default)/ On-grid / Hybrid | | ||
| BATTERY | | | ||
| Battery Type | Li-ion / Lead-Acid / User Defined | | ||
| Rated Battery Voltage | 48Vdc | | ||
| Voltage Range | 40-60Vdc | | ||
| Max.MPPT Charging Current | 200A | | ||
| Max.Mains/Generator Charging Current | 100A | 120A | ||
| Max.Hybrid Charging Current | 180A | 200A | ||
| PV INPUT | | | ||
| Num. of MPP Trackers | 2 | | ||
| Max.PV array power | 5,500W + 5,500W | | ||
| Max.input current | 22A + 22A | | ||
| Max.Voltage of Open Circuit | 500Vdc + 500Vdc | | ||
| MPPT Voltage Range | 125—425Vdc | | ||
| MAINS / GENERATOR INPUT | | | ||
| Input Voltage Range | 90-140Vac | | ||
| Frequency Range | 50/60Hz | | ||
| Bypass Overload Current | 63A | | ||
| EFFICIENCY | | | ||
| MPPT Tracking Efficiency | 99.9% | | ||
| Max. Battery Inverter Efficiency | 92% | | ||
| GENERAL | | | ||
| Dimensions | 620*445*130mm(2*1.46*0.4ft) | | ||
| Weight | 27kg(59.5lb) | | ||
| Protection Degree | IP20,Indoor Only | | ||
| Operating Temperature Range | -15~55℃,>45℃ derated (5~131℉,>113℉ derated) | | ||
| Cooling Method | Internal Fan | | ||
| Warranty | 2 Years | | ||
| COMMUNICATION | | | ||
| Embedded Interfaces | RS485 / CAN / USB / Dry contact | | ||
| External Modules (Optional | Wi-Fi / GPRS | | ||
| CERTIFICATION | | | ||
| Safety | IEC62109-1, IEC62109-2,UL1741 | | ||
| EMC | EN61000-6-1, EN61000-6-3, FCC 15 class B | | ||