Specifications
Operating Temperature :
-25℃~55℃(Derating after 45℃)
Pack Configuration :
52.248kWh/1P52S
Model Number :
Stars CL418 Series
Cycle Life :
≥8,000 cycles
Max.Depth of Discharge :
100%(25±2℃)
Payment Terms :
L/C,T/T
System Configuration :
418kWh/1P416S
Certification :
UN38.3,IEC62619,IEC63056,IEC62477-1,IEC61000-6-2/4
DC Voltage Range :
1164.8~1497.6V
Price :
Negotiable
Rated DC Voltage :
1331.2V
MOQ :
Negotiable
Cell Type :
LFP/314Ah
Brand Name :
Wenergy
Description
Stars CL418 Series Cabinet ESS
Key Highlights
Compact Design
2m² footprint only, easy transportation & fast installation
Efficient Cooling
Optimized in-PACK duct design ensures high-efficiency cooling with reduced energy consumption
Long Cycle Life
Over 8,000 cycles, providing excellent long-term battery performance
High Integration
418kWh energy in one cabinet with remarkable endurance
Flexible Expansion
Modular design, simplified parallel expansion
Ultimate Safety
In-PACK fire warning and protection with aerosol, preventing heat diffusion and runaway
Product Parameters
Model Stars CL418-A400 Stars CL418-A690 Stars CL418-A800
DC Side
Cell Type LFP/314Ah
Pack Configuration 52.248kWh/1P52S
System Configuration 418kWh/1P416S
Rated DC Voltage 1331.2V
DC Voltage Range 1164.8~1497.6V
Max. Charge/Discharge Rate 0.25P 0.5P 0.5P
Max. Depth of Discharge 100%(25±2℃)
AC Side
Rated Output Power 100kW 210kW 210kW
Rated AC Voltage 400V 690V 800V
AC Voltage Range -15%~+10%
Grid Type 3W+PE
Rated Frequency 50Hz/60Hz
Power Factor 0.991-1~+1
THDi ≤3%
DC Ratio <0.5%lpn
General Specifications
Max. Round Trip Efficiency 89%
Cycle Life ≥8,000 cycles
Communication Modbus TCP/IP
Fire Suppression System Aerosol
Ingress Rating IP55
Cooling Liquid cooling + Forced air cooling
Operating Temperature -25℃~55℃ (Derating after 45℃)
Anticorrosion Rating C4 (C5 optional)
Humidity 0~95%RH (non-condensing)
Noise ≤80dB
Altitude 3000m (Derating above 2000m)
Dimensions (W*D*H) 1,500*1,350*2,400 mm
Weight 3800kg
Compliance & Standards
Safety/EMC UN38.3, IEC62619, IEC63056, IEC62477-1, IEC61000-6-2/4
Grid Code EN50549-1-10, EN50549-2/-10, PN^EN-50549-1-2
Send your message to this supplier
Send Now

Stars CL418 Series 418kWh Liquid Cooling Cabinet ESS with 8000 Cycles for Commercial Battery Storage

Ask Latest Price
Operating Temperature :
-25℃~55℃(Derating after 45℃)
Pack Configuration :
52.248kWh/1P52S
Model Number :
Stars CL418 Series
Cycle Life :
≥8,000 cycles
Max.Depth of Discharge :
100%(25±2℃)
Payment Terms :
L/C,T/T
Contact Supplier
Stars CL418 Series 418kWh Liquid Cooling Cabinet ESS with 8000 Cycles for Commercial Battery Storage

Wincle Energy Pte. Ltd.

Verified Supplier
1 Years
Business Type :
Manufacturer, Exporter
Total Annual :
5000000-8000000
Employee Number :
1000~5000
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement