Japan Hamamatsu 90kV Closed-type X-ray Tube for X-ray Counting and Inspection Equipment
Product Overview
Japan Hamamatsu 5 µm 90KV X-ray Tubes
Key Features
- Focal Spot Size: 5 µm (at 4 W)
- High Voltage: No cable connection
- Control Interface: External RS-232C
- Power Output: Maximum 39 W
General Specifications
| Parameter |
Description / Value |
Unit |
| Input Voltage (DC) |
+24 |
V |
| Power Consumption (Max.) |
96 |
W |
| Operating Ambient Temperature |
+10 to +40 |
°C |
| Storage Temperature |
0 to +50 |
°C |
| Operating and Storage Humidity |
Below 85 (No Condensation) |
% |
| Weight |
Approx. 10 |
kg |
| Conformance Standards |
CE(EMC: IEC 61326-1, Group1, Class A) |
- |
| Operation |
Continuous |
- |
| High Voltage Power Supply |
Built-in |
- |
X-ray Tube Specifications
| Parameter |
Description / Value |
Unit |
| X-ray Tube |
Sealed Type |
- |
| X-ray Tube Cooling Method |
Convection Cooling |
- |
| X-ray Tube Window Material / Thickness |
Beryllium / 150 |
µm |
| Target Material |
Tungsten |
- |
| Tube Voltage Operational Range |
20 to 90 |
kV |
| Tube Current Operational Range |
10 to 200 (8 W Max) |
μA |
| Maximum Output |
8 |
W |
| X-ray Focal Spot Size |
7 (5 µm at 4 W) |
µm |
| X-ray Beam Angle (Coned) |
39 |
degrees |
| Focus to Object Distance (FDF) |
9.5 |
mm |
X-ray Control Specifications
| Parameter |
Description / Value |
Unit |
| Function |
Tube Voltage and Tube Current Preset / Auto Warm-up |
- |
| Protection |
Interlock |
- |
| External Control |
RS-232C |
- |
| Applicable OS |
Windows 2000 Professional, XP Professional |
- |
| Computer Operating Conditions |
CPU: Intel Pentium or Higher, Memory: 64 MB or More |
- |
Tube Current Operational Range
Dimensional Outline
Applications
- Non-destructive inspection
- X-ray CT scanning
Applicable Objects
- Electronic components
- Printed circuit boards
- Plastic components
- Metal components
Related Products