0.75KW-11KW VFD 220V input 380v output variable frequency inverter
 
| Item | Specifications | ||
  Standard functions  | Maximum frequency | Vector control:0~500Hz V/F control: 0~500Hz | |
 Carrier frequency  | 0.5kHz~16kHz (The carrier frequency is automatically adjusted based on the load features.) | ||
Input frequency resolution  | Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.025%  | ||
 Control mode  | Sensor-less flux vector control (SFVC) Closed-loop vector control (CLVC) (+PG Card) Voltage/Frequency (V/F) control  | ||
| Startup torque | 0.5Hz/150%(SVC);0Hz/180%(FVC) | ||
| Speed range | 1:100 (SVC) | 1:1000 (FVC) | |
| Speed stability accuracy | ±0.5%(SVC) | ±0.02%(FVC) | |
| Torque control accuracy | ±5%(FVC) | ||
  Overload capacity  | G type: 60s for 150% of the rated current, 3s for 180% of the rated current P type: 60s for 120% of the rated current, 3s for 150% of the rated current  | ||
 Torque boost  | Auto boost; Manual boost: 0.1%~30.0%  | ||
| Standard functions |   V/F curve  | Straight-line V/F curve Multi-point V/F curve N-powerV/F curve (1.2-power, 1.4-power, 1.6-power, 1.8- power, square)  | 
| V/F separation | 2 types: complete separation; half separation | |
  Acceleration/deceleration curve  | Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time with the range of 0.00s~65000s  | |
  DC braking  | 
 DC braking frequency: 0.00 Hz ~ maximum frequency Braking time: 0.0~100.0s Braking trigger current value: 0.0%~100.0%  | |
 JOG control  | 
 JOG frequency range: 0.00Hz~50.00 Hz JOG acceleration/deceleration time: 0.00s~65000s  | |
| Built-in PLC, multiple speeds | 
 It realizes up to 16 speeds via the simple PLC function or combination of DI terminal states  | |
| Built-in PID | It realizes closed loop control system easily. | |
| Auto voltage regulation (AVR) | 
 It can keep constant output voltage automatically when the mains voltage fluctuation.  | |
| Overvoltage/ Over current stall control | The current and voltage are limited automatically during the running process so as to avoid frequently tripping due to overvoltage/over current.  | |
Rapid current limit function  | It can auto limit running current of frequency inverter to avoid frequently tripping. | |
  Torque limit and control  | (Excavator characteristics) It can limit the torque automatically and prevent frequently over current tripping during the running process. Torque control can be implemented in the VC mode.  | 
 
VFD200A picture:


 
Connect wire diagram: