30A MPPT Solar Regulator - 12V to 48V Auto-Switch Smart Charge Controller for Solar Panels
Ideal Applications:
-
Off-grid home solar systems
-
RV and marine power solutions
-
Remote cabins and telecommunications
-
Agricultural and industrial solar installations
Engineered for reliability and built to withstand harsh environments, our MPPT Solar Charge Controller delivers professional-grade performance for both residential and commercial solar applications. The automatic operation ensures worry-free power management while the advanced MPPT technology guarantees you get the most from your solar investment.
| Product Name | MPS 30A | MPS 40A | MPS 60A | MPS 80A | MPS 100A |
| System Rated Voltage | 12/24/36/48VDC or Self-identification |
| Controller operating voltage range | 12-64V |
| Lead-acid battery type | Maintenance-free(default) /Colloid /Liquid /Custom |
| Lithium battery type | Lithium Iron Phosphate /Ternary Lithium /Custom |
| Rated charging current | 30A | 40A | 60A | 80A | 100A |
| Rated charging power | 390W /12V | 540W/12V | 800W/12V | 1040W/12V | 1300W/12V |
| 1080W/24V | 1600W/24V | 2080W/24V | 2600W/24V |
| 1620W/36V | 2400W/36V | 3120W/36V | 3900W/36V |
| 2160W/48V | 3200W/48V | 4160W/48V | 5200W/48V |
| Maximum open ccircuit voltage of photovoltaic modules | 150V (under the lowest temperature condition) 138V (under 25℃ condition) |
| Maximum power point operating voltage range | 12V System | 20~150VDC |
| 24V System | 36~150VDC |
| 36V System | 48~150VDC |
| 48V System | 64~150VDC |
| Tracking efficiency | ≥99.5% |
| Maximum conversion efficiency | 97.50% |
| Temperature compensation coefficient | -3mV/ ℃ /2V |
| Statuc loss | 350mA/12V: 170mA/24V: 85mA/48V | 700mA/12V: 350mA/24V: 175mA/48V |
| DC Load output voltage | Can be turned on in 12V/24V Moode |
| DC load rated output current | 40A |
| DC load output control | Normally open ormally closed mode /Time control mode /Light control mode |
| Protective function | PV input reverse connection protection |
| Battery input reverse connection protection |
| Battery overcharge protection |
| Battery under voltage protection |
| Battery over tempearature protection |
| Machine over temperature protection |
| Colling Method | Wind cooling |
| Way of communication | RS485 |
| LDC Backlight time | Default 60S, Backlight mode cab be set |
| Environmental parameters |
| Working environment temperature range | -20℃ ~+50℃ |
| Storage temperature range | -40℃ ~+70℃ |
| Relative humidity range | 0 ~ 90%RH |
| Mechanical parameters |
| Dimensions | 210*150*80mm | 219*300*110mm | 219*300*110mm | 275*363*109mm | 275*363*109mm |
| Recommened wiring | 9AWG/6mm² | 7AWG/6mm² | 6AWG/6mm² | 4AWG/6mm² | 2AWG/6mm² |
| Net weight | 1.45kg | 2.94kg | 2.94kg | 4.56kg | 4.56kg |