Max PV Voltage 48V 12V 24V 20A 250W Solar Panel Charge Controller with Advanced MPPT Technology









|  			 Parameters/Model  			 |  			 			 MN10  			 |  			 			 MN20  			 |  			 			 MN30  			 |  			 			 MN40  			 |  		||||
|  			 Maximum Power Current  			 |  			 			 12A  			 |  			 			 20A  			 |  			 			 30A  			 |  			 			 40A  			 |  		||||
|  			 Installation Lin mm2  			 |  			 			 4mm2  			 |  			 			 8mm2  			 |  			 			 10mm2  			 |  			 			 12mm2  			 |  		||||
|  			 Installation Line(AWG)  			 |  			 			 10 (AWG)  			 |  			 			 8(AWG)  			 |  			 			 7(AWG)  			 |  			 			 6(AWG)  			 |  		||||
|  			 Weight  			 |  			 			 280g  			 |  			 			 300g  			 |  			 			 475g  			 |  			 			 480g  			 |  		||||
|  			 Dimensions  			 |  			 			 143×89×46 mm  			 |  			 			 |  			 			 187*97*61 mm  			 |  			 			 |  		||||
|  			 System load loss  			 |  			 			 ≤13mA  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Loop Buck  			 |  			 			 ≤100mV  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Battery float voltage  			 |  			 			 13.8V 12V system /27.6V 24V system  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Battery under voltage) protection  			 |  			 			 10.6V 12V system /21.2V 24V system  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Battery (under voltage) recovery voltage  			 |  			 			 12.6V 12V system /25.2V 24V system  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Charge mode  			 |  			 			 MPPT MODE  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Operating Temperature  			 |  			 			 -10~60°C  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Storage Temperature  			 |  			 			 -30~70°C  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Humidity requirements  			 |  			 			 ≤90%, No condensation  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Temperature compensation  			 |  			 			 -4mV/Cell/°C  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Temperature Probe (built components)  			 |  			 			 TC 100K thermistats  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 aximum open circuit voltage of the solar panel  			 |  			 			 18V-24V 12V system 36V-48V 24V system)  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Solar panels maximum open circuit voltage (V)  			 |  			 			 ≤48V  			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 (Cases) 12V system standard configuration  			 |  			 			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 The peak voltage of the solar cell panel  			 |  			 			 18V-25V  			 |  			 			 18V-25V  			 |  			 			 18V-25V  			 |  			 			 18V-25V  			 |  		||||
|  			 Peak power of solar cell panel  			 |  			 			 50W-130W  			 |  			 			 100W-260W  			 |  			 			 200W-380W  			 |  			 			 ≤500W  			 |  		||||