Specifications
Brand Name :
Keithley
Model Number :
2601-PULSE
Place of Origin :
China
MOQ :
1 set
Price :
Negotiation
Payment Terms :
T/T
Supply Ability :
in stock
Product name :
SourceMeter
Max Current :
10A
Max Voltage :
40V
Power :
100W 200W
Condition :
Pre-Owned
Functions :
Tested, in Full Working Conditions
Description
Keithley 2601B-PULSE 10A 10V Source Measure Unit with 10µs Pulse
Product Overview
The Keithley 2601B-PULSE is a high-performance Source Measure Unit with integrated 10 µsec pulser functionality. Its advanced control loop system eliminates the need for manual tuning with load changes up to 3 μH, ensuring clean pulse output without overshoot and ringing when delivering pulses from 10 μs to 500 μs at current levels up to 10 amps.
Key Performance Features
  • Output 10 A @ 10 V with 10 μs pulse width capability
  • Pulse rise time <1.7 μs for precise device characterization
  • High fidelity pulse output without tuning at any current level
  • Pulser 0.05% basic measure accuracy with 1 MS/s digitizing
  • SMU 100 nA low current range with 100 fA sensitivity
  • Rear panel BNC connections for simplified cable setup
Advanced Technology
Test Script Processor (TSP®) technology embeds and executes complete test programs directly within the SMU instrument, delivering industry-leading performance. TSP-Link® technology enables expansion of up to 32 nodes for creating high-speed, SMU-per-pin parallel testing without requiring a mainframe.
  • Eliminates time-consuming bus communications to and from PC
  • Advanced data processing and flow control capabilities
  • Connect up to 32 TSP-Link nodes for scalable testing
  • Easy reconfiguration as test requirements evolve
Technical Specifications
This document contains specifications and supplemental information for the 2601B-PULSE System SourceMeter 10 µs Pulser/SMU Instrument. Specifications represent the standards against which the instrument is tested and validated before leaving the factory.
Accuracy specifications apply to both normal and High Capacitance modes. Source and measurement accuracies are specified at the instrument terminals under the following conditions:
  • Operating temperature: 18 °C to 28 °C, <70% relative humidity
  • After 2-hour warm-up period
  • Speed normal (1 NPLC) operation
  • A/D auto-zero enabled
  • Remote sense operation or properly zeroed local operation
  • Calibration period = 1 year
Pulser feature specification accuracies require:
  • 10 μs aperture minimum
  • Remote sense operation only
  • Total cable and DUT inductance of ≤3 μH, measured at 100 kHz
Additional Features
  • Industry leading 10 A @ 10 V, 10 microsecond pulse output
  • Comprehensive interfaces: USB 2.0, LXI Core, GPIB, RS-232, and digital I/O
  • TSP-Link expansion technology for multi-channel parallel testing
  • TSP technology for embedded test programs and superior system throughput
  • DC capability up to ±40 V @ ±1.0 A, 40 Watt
  • Dual 1 Megasample/second digitizers for high-speed I/V pulse measurements
  • Supported in Keithley KickStart non-programming software tool
  • No tuning required; compatible with inductive loads up to 3 μH
Product Images
Send your message to this supplier
Send Now

Keithley 2601B-PULSE Source Measure Unit with 10A @ 10V 10µs Pulse Width and No Tuning Required

Ask Latest Price
Brand Name :
Keithley
Model Number :
2601-PULSE
Place of Origin :
China
MOQ :
1 set
Price :
Negotiation
Payment Terms :
T/T
Contact Supplier
Keithley 2601B-PULSE Source Measure Unit with 10A @ 10V 10µs Pulse Width and No Tuning Required
Keithley 2601B-PULSE Source Measure Unit with 10A @ 10V 10µs Pulse Width and No Tuning Required
Keithley 2601B-PULSE Source Measure Unit with 10A @ 10V 10µs Pulse Width and No Tuning Required

Shenzhen Meigaolan Electronic Instrument Co. Ltd

Verified Supplier
4 Years
shenzhen
Since 2003
Business Type :
Distributor/Wholesaler
Total Annual :
500000-1000000
Employee Number :
>100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement