FPM-07PG Pressure Sensor For Medical Electronics Wearable Devices
It can be used in disposable sphygmomanometers, vacuum cleaners, washing machines, inflation devices, pressure switches, multi - parameter monitors, hematology analyzers and other equipment, and is also applicable to the consumer and sports fields. In addition, it is widely used in instrument and meter, automotive electronics, home appliances, medical equipment, portable devices and other industries.
- Features:
- Good pressure tracking12: It has a good ability to track pressure changes, which can quickly and accurately reflect the pressure change situation.
- Micro - pressure operation: It can operate through micro - pressure, which is suitable for occasions where micro - pressure measurement is required.
- Stable start - up after long - term stop: Even after long - term stop, it can start stably without abnormal jitter or other situations.
- Wide temperature range: The operating temperature range is from - 20°C to 100°C, which can adapt to a variety of environmental temperatures.
- Analog output with amplification and temperature compensation8: It has an analog output with amplification and temperature compensation functions, which can ensure the accuracy of the output signal and reduce the influence of temperature on the measurement result.
- High overall accuracy: The overall accuracy can reach ±1.5%FS, which can provide relatively accurate pressure measurement data.
- Wide power supply voltage support: It supports power supply voltages of 3.0V, 3.3V, and 5.0Vdc, and has strong adaptability to the power supply.
- Low - power consumption: The power consumption is low, with a maximum of 2mA at 3.3Vdc, which is suitable for battery - powered devices.
- Compatible with terminal layout: The terminal layout and shape are compatible with the XFPM series of integrated sensors, which is convenient for replacement and integration.
- Customizable specifications: Customizable specifications can be provided according to customer needs to meet different application requirements.
Output Signal | Analog voltage |
Measurable Pressure Range | - 98.07 kPa to 103.4 kPa (gauge) |
Rated Pressure | 103.4 kPa |
Maximum Load Pressure | 2 times the rated pressure |
Output Voltage | 60 mV to 140 mV (at 0 kPa to rated pressure) |
Maximum Operating Current | 1.5 mA |
Offset - Nom | 20 mV |
Operating Temperature Range | - 20 °C to 100 °C |
Storage Temperature Range | - 40 °C to 120 °C |
Response Time | 2000 μs |
Mounting Feature | Through - hole mount |
Termination Type | Solder |
Body Breadth | 12.0 mm |
Body Height | 4.0 mm |
Body Length or Diameter | 14.0 mm |
Repeatability | ±0.02 |