65W/24V Desktop Power Adapter
Key Features
- 100% full-load aging test
- Input voltage: 200VAC-264VAC
- Fanless, completely quiet operation
- High efficiency, long life and high reliability
- Operating temperature range: -20℃~+65℃
- Protection function: short-circuit/overload/overvoltage
Technical Specifications
| Model |
GWS-AP65-24 |
| Output |
| No. of Output Group |
1 |
| DC Voltage |
24VDC |
| Output Current Range |
0-2.7A |
| Ripple Noise: 0℃<Ta≤55℃ |
≤50mVp-p |
| Ripple Noise: -15℃≤Ta≤0℃ |
≤100mVp-p |
| Stabilized Voltage Precision |
±1% |
| Line Regulation |
±1% |
| Load Regulation |
±1% |
| Temperature Coefficient |
±0.03%/℃ |
| Output Start-up Time |
≤3.0S (120VAC input, full load), ≤2.0S (220VAC input, full load) |
| Output Hold-up Time |
≥10mS (120VAC input, full load), ≥20mS (220VAC input, full load) |
| Voltage Overshoot |
<5.0% |
| Input |
| Input Voltage Range |
90VAC~264VAC |
| Input Rated Voltage Range |
100VAC~240VAC |
| Frequency Range |
47Hz~63Hz |
| Efficiency |
87% |
| Input Current |
<0.7A |
| Inrush Starting Current |
<40A@300VAC cold start |
| Leakage Current |
Input to output≤ 0.25mA |
| Output Protection |
| Overpower Protection |
54W-97.5W down |
| Overvoltage Protection |
28V-29V down |
| Overcurrent Protection |
3.25A-4.05A down |
| Short-circuit Protection |
Sustainable for prolonged short circuits, automatically recovers after the short circuit is cleared. |
| Operation Environment |
| Operation TEMP/ Humidity |
-20℃~65℃, 20%~90%RH |
| Storage TEMP/ Humidity |
-40℃~85℃, 5%~95%RH Non-condensing |
| Safety and EMC Standard |
| Safety Standard |
GB4943/EN62368 |
| Insulation Strength |
Input-Output: 3KVac/10mA; Input-Ground: 1.5KVac/10mA; Output-Ground: 0.5KVDC/10mA; Test time: 1min |
| Insulation Impedance |
Input-Output: 100M ohms; Input-Enclosure: 100M ohms; Output-Enclosure: 100M ohms |
| Electromagnetic Interference |
EN55022 Class A |
| Harmonic Current |
IEC61000-3-2 Class A equipment requirements |
| Electromagnetic Immunity |
EN61000-4-2, 4,5,6,8,11 ENV50204, Class A heavy industry standard |
| Others |
| MTBF |
100,000Hrs at 25℃, MIL-217 Method 2 components stress method |
| Dimension |
125*51*32mm |
| Net Weight |
0.195kg |
| Warranty |
2 years, lifelong maintenance |
Dimensions
All specifications were measured at rated input, rated load, and 25°C ambient temperature. Ripple noise test method: Use a 12# twisted-pair cable, with 0.1uF and 10uF capacitors connected in parallel at the termination. Measure using an oscilloscope with a 20MHz bandwidth. The power supply will be installed as a component in the final device, which must still meet EMC requirements.