250W/52V Desktop Power Adapter
Product Features
- 100% full-load aging test
- Input voltage: 200VAC-264VAC
- Fanless, completely quiet operation
- High efficiency, long life and high reliability
- Operating temperature range: -20℃~+65℃
- Protection function: short-circuit/overload/overvoltage
Technical Specifications
| Model |
GWS-AP250-52 |
| Output |
| No. of Output Group |
1 |
| DC Voltage |
52VDC |
| Output Current Range |
0-4.5A |
| Ripple Noise |
<300mVp-p (Vin 240Vac/50Hz full load) |
| Voltage Regulation Accuracy |
±3% |
| Source Regulation |
±1% |
| Load Regulation |
±3% |
| Temperature Coefficient |
±0.03%/℃ |
| Output Start-up Time |
≤2.0S (220VAC input, full load) |
| Output Hold-up Time |
≥20mS (The power shall support 4.95A at 200-240VAC and 25℃) |
| Voltage Overshoot |
<5.0% |
| Input |
| Input Voltage Range |
200VAC~264VAC |
| Rated Input Voltage Range |
200VAC~240VAC |
| Frequency Range |
47Hz~63Hz |
| Efficiency |
89% |
| Input Current |
<2.2A |
| Start-up Inrush Current |
<40A@300VAC cold start |
| Leakage Current |
Input to output ≤ 0.25mA |
| Protection Function |
| Overpower Protection |
290W~360W down |
| Overvoltage Protection |
59V~60V down |
| Overcurrent Protection |
6A~6.6A down |
| Short-circuit Protection |
Sustainable for prolonged short circuits; automatically recovers after the short circuit is cleared. |
| Operation Environment |
| Operation TEMP/ Humidity |
-20℃~+65℃, 20%-90%RH non-condensing |
| Storage TEMP/ Humidity |
-20℃~+80℃, 5%-90%RH non-condensing |
| Safety and EMC Standard |
| Safety Standard |
GB4943/EN62368 |
| Insulation Strength |
Input-Output: 3KVac/10mA; Input-Ground: 1.5KVac/10mA; Output-Ground: 0.5KVDC/10mA; Test time: 1min |
| Insulation Impedance |
Input-Output: 100M ohms; Input-Enclosure: 100M ohms; Output-Enclosure: 100M ohms |
| Electromagnetic Interference |
EN55022 Class A |
| Harmonic Current |
IEC61000-3-2 Class A equipment requirements |
| Electromagnetic Immunity |
EN61000-4-2, 4,5,6,8,11 ENV50204, Class A heavy industry standard |
| Others |
| MTBF |
100,000Hrs at 25℃, MIL-227 Method 2 components stress method |
| Dimension |
186*80*40mm |
| Net/Gross Weight |
1.19kg/ 1.28kg |
| Warranty |
2 years, lifelong maintenance |
All specifications were measured at rated input, rated load, and 25°C ambient temperature. Ripple noise test method: Use a 12# twisted-pair cable, with 0.1uF and 10uF capacitors connected in parallel at the termination. Measure using an oscilloscope with a 20MHz bandwidth. The power supply will be installed as a component in the final device, which must still meet EMC requirements.