Specifications
Application :
Insulation for roofs, walls, floors
Model Number :
PUR-PS120
Wall Thickness :
40 - 80 mm
Environmental Impact :
CFC/HCFC free, recyclable
Surface Facing :
Aluminum foil, glass tissue, or kraft paper
Delivery Time :
2-3weeks
Fire Performance :
GB 8624 Class B1, self extinguishing
Thermal Conductivity :
<= 0.023 W/(m.K) at 20 C
Brand Name :
MYREAL
Installation Method :
Adhesive bonding, mechanical fixing
Panel Thickness :
20 mm to 200 mm
Moisture Vapor Transmission :
Low permeability
product name :
District Heating PUR Pipe Section Insulation
Place of Origin :
China
Supply Ability :
Subject to order quantity and specifications
Core Density :
45 - 55 kg/m3 (50 +/- 5)
Water Absorption :
<= 5% volumetric
Density :
30 - 40 kg/m³
Fire Resistance :
Class B-s1,d0 (EN 13501-1)
Dimensional Stability :
≤ 1% change
Operating Temperature Range :
-50°C to +120°C
Compressive Strength :
>= 200 kPa
Product Type :
Preformed PUR pipe section for heating networks
Certification :
ISO、SGS、CE
Core Material :
Polyisocyanurate (PIR)
Service Temperature :
-80 to 100 C
Pipe Size Range :
DN25 - DN600
Type :
Polyurethane Rigid Foam
Packaging Details :
Cartons / PE Bags
MOQ :
1 carton
Payment Terms :
T/T
Description

District Heating PUR Pipe Section Insulation for Steam Line Service 120 C

District heating networks need insulation that survives heat, ground water and traffic load at the same time. This PUR pipe section insulation is moulded at fifty kilograms per cubic metre and banded to the pipe, so the shell stays tight while the line expands and contracts through the heating season.

The closed cell structure keeps water absorption below five percent by volume, which matters in buried ducts where the insulation can sit in contact with groundwater for decades. Conductivity of 0.023 W/(m.K) keeps heat loss per metre low, and the shell is dimensioned to fit standard DN sizes without gaps at the butt joints.

For steam service we confirm the actual operating temperature before quoting, because standard PUR suits continuous duty up to about 100 degrees and short excursions to 120. Where the line runs hotter, we recommend a PIR or mineral based solution instead, and we will say so rather than sell a shell that will fail early.

A district heating PUR pipe section is banded at 300 mm centres, and every district heating PUR pipe section is checked for roundness before dispatch. Where a district heating PUR pipe section meets a valve we supply a matching box section, and a district heating PUR pipe section ordered for a buried line receives an HDPE jacket. Each district heating PUR pipe section is packed with its joint sleeves.

Key Advantages

  • Moulded shells at 50 kg/m3 keep shape under pipe movement
  • Closed cell foam with water absorption below five percent
  • Conductivity 0.023 W/(m.K) cuts heat loss per metre
  • Sized to standard DN pipe diameters for tight butt joints
  • Steel band fixing suits buried and above ground networks
  • Temperature advice given honestly before quotation

Technical Specifications

product nameDistrict Heating PUR Pipe Section Insulation
Product TypePreformed PUR pipe section for heating networks
Core MaterialRigid polyurethane foam, closed cell
Core Density45 - 55 kg/m3 (50 +/- 5)
Thermal Conductivity<= 0.023 W/(m.K) at 20 C
Compressive Strength>= 200 kPa
Water Absorption<= 5% volumetric
Fire PerformanceGB 8624 Class B1, self extinguishing
Service Temperature-80 to 100 C
Wall Thickness40 - 80 mm
Pipe Size RangeDN25 - DN600
ApplicationDistrict heating steam and condensate line insulation

Typical Applications

  • District heating supply and return lines
  • Steam and condensate pipework
  • Buried pre-insulated pipe systems
  • Plant room headers and manifolds
  • Industrial process steam lines
  • Municipal heat network retrofits

Frequently Asked Questions

Q: What is the maximum continuous temperature?

A: Around 100 degrees continuous for standard PUR, with short excursions to 120. Above that we recommend a different foam system.

Q: How are sections fixed to the pipe?

A: Stainless or galvanised steel bands at 300 to 500 mm centres, with the joint adhesive applied first.

Q: Can you supply outer cladding?

A: Yes, HDPE, galvanised steel or aluminium cladding is available for buried and outdoor service.

Q: Do you produce matching elbows and tees?

A: Yes, factory made elbows, tees and reducers are produced to the same density and thickness as the straight sections.

MYREAL supplies PUR pipe section insulation for district heating from Shanghai to projects in Europe, the Middle East and Southeast Asia. Contact our technical team for datasheets, samples and container plans.

Send your message to this supplier
Send Now

District Heating PUR Pipe Section Insulation For Steam Line Service 120 c

Ask Latest Price
Application :
Insulation for roofs, walls, floors
Model Number :
PUR-PS120
Wall Thickness :
40 - 80 mm
Environmental Impact :
CFC/HCFC free, recyclable
Surface Facing :
Aluminum foil, glass tissue, or kraft paper
Delivery Time :
2-3weeks
Contact Supplier
District Heating PUR Pipe Section Insulation For Steam Line Service 120 c

Myreal Energy Saving (Shanghai) Co., Ltd.

Verified Supplier
1 Years
shanghai, shanghai
Since 2014
Total Annual :
5000000-10000000
Employee Number :
11~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement