Industrial Energy Management Control Panel for Plant Operations
Product Describe:
1. Sensor and metering module
High energy consuming equipment is equipped with high-precision sensors (± 0.5%) to monitor power factor and harmonics; Economical electricity meters (± 1%) are used in ordinary areas.
Choose explosion-proof type for hazardous areas, waterproof and corrosion-resistant type for humid environments, and reserve metering interfaces when integrating new energy.
2. Control logic and algorithms
Prioritize load balancing in industrial scenarios and start high-power equipment off peak; Combining pedestrian flow regulation with air conditioning in commercial buildings can save 30% -40% energy; Data center linkage temperature control to avoid excessive cooling.
Constant parameter system optimizes PID parameters to shorten the response time to load fluctuations.
3. Execution mechanism and load
Match the frequency converter to achieve 10% -100% smooth speed regulation, and set up independent protection circuits for mixed loads.
Key facilities are linked to UPS or generators to ensure the operation of core loads during power outages.
4. Communication and Data
Compatible with standard protocols to interface with upper level systems, with 5G/LoRa modules added for dispersed scenarios.
Customize local storage (such as 6-month data) and edge computing functions.
5. Cabinet and Environment
IP65 cabinet for outdoor use, IP54 cabinet for high humidity areas with temperature and humidity control.
Install heat dissipation devices in the high-power component area to control the temperature below 40 ℃.
Design:
Model |
Size:W*L*D,mm |
1 |
300×400×160 |
2 |
300×400×200 |
3 |
300×400×250 |
4 |
400×500×200 |
5 |
400×500×250 |
6 |
400×500×300 |
7 |
400×600×200 |
8 |
400×600×250 |
9 |
500×600×200 |
10 |
500×600×250 |
11 |
500×600×300 |
12 |
500×700×200 |
13 |
500×700×250 |
14 |
600×700×200 |
15 |
600×800×200 |
16 |
600×800×250 |
17 |
600×800×300 |
18 |
700×900×200 |
19 |
700×900×250 |
20 |
800×1000×200 |
21 |
800×1000×250 |
22 |
800×1000×300 |
Customize |
—— |
IP Grade:
IP 30 / IP 40 / IP54 / IP55 / IP65 / IP66
Suggestion:
For DDC energy control systems, key customizations include: Sensor & metering modules: high-precision sensors (±0.5%) for high-energy equipment, economical meters (±1%) for general areas; explosion-proof/waterproof models for harsh environments, with new energy metering interfaces reserved. Control logic: prioritize load balancing in industrial settings, adjust AC by passenger flow (30-40% energy savings) in commercial buildings, link temperature control in data centers, and optimize PID for constant-parameter systems. Actuators: match frequency converters (10-100% speed), set independent protection for mixed loads, and link critical facilities to UPS/generators. Communication: support standard protocols, add 5G/LoRa for decentralized use, with 6-month local storage and edge computing. Cabinets: IP65 for outdoors, IP54 with temperature/humidity control for high humidity; cooling devices to keep temperatures below 40°C.