Specifications
Brand Name :
Quenda
Model Number :
QS-2830
Certification :
CE,ISO
Place of Origin :
QINGDAO,CHINA
MOQ :
1set
Price :
USD10000-50000
Payment Terms :
T/T
Supply Ability :
200set per month
Delivery Time :
7-10days
Packaging Details :
Carton
Wavelength Range :
190nm~900nm
Spectral Bandwidth :
0.2, 0.4, 1.0, 2.0nm (automatic switching)
Number of Sample Cups :
50 sample cups(1.5mL); 2 reagent cups(10mL)
Sample Volume :
1~50μL
Repeatability :
≤0.5% (5~50μL)
Host Size(W*D*H) :
872mm*560mm*460mm
Description

Atomic Absorption Spectrometer AAS With Deuterium lamp (D2) background correction

AAS Performance characteristics

  • The integrated design of flame graphite furnace can be switched with one key;

  • Deuterium lamp (D2) background correction.;

  • It is equipped with water seal detection, waste liquid level detection, gas pressure monitoring and flame monitoring;

  • It is equipped with perfect interlocking protection device and anti tempering device to automatically shut down the gas in case of accidental flameout;

  • Vertical 8-element lamp design, eight lamps are preheated at the same time;

  • 52 position graphite furnace automatic sampler;

  • Atomization system;

  • Titanium alloy combustion head, all plastic atomization chamber, corrosion resistance;

  • Glass atomizer is adopted, which is corrosion-resistant and easy to clean;

  • 10 step heating program, three heating modes: step, slope and hold;

  • Longitudinal heating technology.

AAS ​Technical Parameter

Power Supply 220V±10% AC; 300VA; 50Hz±1Hz
Operation Temperature 10℃~30℃
Technical Condition Operation Humidity ≤ 75%
Host Size(W*D*H) 872mm*560mm*460mm
Weight 85kg
Wavelength Range 190nm~900nm
Spectroscopic System

Monochromator

Optical Grating

C-T (Czerny-turner)type; Focal length: 270mm

1800 pieces/mm

Spectral Bandwidth 0.2, 0.4, 1.0, 2.0nm (automatic switching)
Number of Sample Cups 50 sample cups(1.5mL); 2 reagent cups(10mL)
Sample Volume 1~50μL
Repeatability ≤0.5% (5~50μL)
AS-100 Automatic Sampler

Power Requirement

Size(W*D*H)

DC24V; 40W

350mm*280mm*180mm

Weight
inclined injection
single injection pump
5℃~35℃
±1℃
900W @25℃
8L
0.05Mpa~0.15Mpa
2-10L/min
360mm*450mm*660mm
Power Supply 220V±10% AC; 50Hz
Output Power/Speed 600W/1400V/min
Starting Pressure
YH-04 Low Noise Oil-free Air Compressor

0.75mp

60L/min(0.4mp)

28L
<58dB(A)


Authentication

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction

Exhibition

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction


Instrument commissioning and training

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction

Customer visit

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction

Add: No.151, Zhuzhou Road, Laoshan District, Qingdao, Shandong, China

Send your message to this supplier
Send Now

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction

Ask Latest Price
Brand Name :
Quenda
Model Number :
QS-2830
Certification :
CE,ISO
Place of Origin :
QINGDAO,CHINA
MOQ :
1set
Price :
USD10000-50000
Contact Supplier
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction

Qingdao Qingyuanfengda Import and Export Co., Ltd

Active Member
5 Years
shandong, qingdao
Since 2002
Business Type :
Manufacturer, Distributor/Wholesaler, Importer, Exporter, Trading Company
Total Annual :
3000000-3500000
Employee Number :
100~200
Certification Level :
Active Member
Contact Supplier
Submit Requirement