Executive Standard
This product implements: IEC60092-354 standard.
Cable Categories and Types
- CJPJ/SC: XLPE insulated crosslinked polyolefin outer sheathed Marine power cable type SC
- CJV/DNSA: XLPE insulated PVC sheathed marine power cable DA/SA type
- CJPJ85/SC: XLPE insulated crosslinked polyolefin inner sheath, Copper wire braided armoring, crosslinked polyolefin outer sheath marine power cable type SC
- CJPJ95/SC: XLPE insulated crosslinked polyolefin inner sheathed wire braided armoring, crosslinked polyolefin outer sheathed marine power cable Type SC
- CJV82/DNSA: XLPE insulated PVC inner sheathed copper wire braided armored PVC outer sheathed marine power cable DA/SA type
- CJV92/DNSA: XLPE insulated PVC inner sheathed wire braided armored PVC outer sheathed marine power cable DA/SA type
Product Application
This product is suitable for electric power devices in water structures such as cabins and offshore oil platforms.
Cable Parameters
Rated voltage: 3.6/6 (7.2) kV
| No. of cores x sectional area |
CJPJ/SC CJV/DNSA |
CJPJ85/SC CJPJ95/SC CJV82/DNSA CJV92/DNSA |
| Over diam. mm |
Approx weight |
Over diam. mm |
Approx weight |
| |
Nom |
Max |
Type 82/85 |
Type 92/95 |
Nom |
Max |
Type 82/85 |
Type 92/95 |
| 1x10 |
15.1 |
17.3 |
370 |
|
17.9 |
20.5 |
571 |
561 |
| 1x16 |
16.0 |
18.4 |
446 |
|
18.8 |
21.6 |
657 |
646 |
| 1x25 |
17.6 |
20.2 |
573 |
|
20.6 |
23.6 |
815 |
803 |
| 1x35 |
18.6 |
21.3 |
689 |
|
21.6 |
24.8 |
943 |
931 |
| 1x50 |
20.0 |
23.0 |
841 |
|
23.6 |
27.1 |
1137 |
1124 |
| 1x70 |
21.6 |
24.8 |
1072 |
|
25.4 |
29.2 |
1403 |
1389 |
| 1x95 |
23.5 |
27.0 |
1364 |
|
27.5 |
31.6 |
1755 |
1735 |
| 1x120 |
24.7 |
28.4 |
1611 |
|
28.7 |
33.0 |
2020 |
2000 |
| 1x150 |
26.5 |
30.4 |
1915 |
|
30.7 |
35.3 |
2369 |
2347 |
| 1x185 |
28.3 |
32.5 |
2297 |
|
32.5 |
37.3 |
2779 |
2756 |
| 1x240 |
31.1 |
35.7 |
2898 |
|
35.5 |
40.8 |
3444 |
3418 |
| 1x300 |
33.6 |
38.6 |
3528 |
|
38.2 |
43.9 |
4135 |
4107 |
| 3x10 |
30.0 |
34.5 |
1371 |
|
34.4 |
39.6 |
1906 |
1881 |
| 3x16 |
32.2 |
37.0 |
1662 |
|
36.6 |
42.0 |
2232 |
2205 |
| 3x25 |
35.4 |
40.7 |
2114 |
|
40.0 |
46.0 |
2758 |
2729 |
| 3x35 |
37.7 |
43.4 |
2548 |
|
42.5 |
48.9 |
3255 |
3224 |
| 3x50 |
40.5 |
46.6 |
3079 |
|
45.5 |
52.3 |
3860 |
3827 |
| 3x70 |
44.2 |
50.8 |
3919 |
|
49.2 |
56.5 |
4764 |
4728 |
| 3x95 |
48.2 |
55.5 |
4952 |
|
53.4 |
61.4 |
5900 |
5860 |
| 3x120 |
51.0 |
58.7 |
5835 |
|
56.6 |
65.1 |
6937 |
6887 |
| 3x150 |
54.6 |
62.8 |
6894 |
|
60.4 |
69.5 |
8103 |
8049 |
| 3x185 |
58.5 |
67.3 |
8230 |
|
64.5 |
74.2 |
9554 |
9497 |
Note: The above are the commonly used typical voltage levels and model specifications. If you need other model voltage levels, please consult our company's technical department.
Main Technical Characteristics
- The rated voltage of the cable is 3.6(7.2)kV, 6/10(12)kV, 8.7/15(17.5)kV
- The allowable long-term operating temperature of the cable conductor is 90°C
- The flame retardant performance of the cable conforms to IEC80332-1-2 IEC80332-3-22 standard
- The fire resistance of the cable conforms to IEC80331-21 standard
- The minimum bending radius of a single-core cable is 12 times the outer diameter of the cable, and the minimum bending radius of a 3-core cable is 9 times the outer diameter of the cable