6/10kV Rated Voltage Marine Power Cable Crosslinked Polyethylene Insulation and Flame Retardant Properties
6/10kV Rated Voltage Marine Power Cable
Crosslinked Polyethylene Insulated Marine Power Cable at rated voltage
Executive Standard
This product implements: IEC60092-354 standard.
Cable Categories and Types
- CJPJ/SC: XLPE insulated crosslinked polyolefin outer sheathed Marine power cable type SC
- CJV/DNSA: XLPE insulated PVC sheathed marine power cable DA/SA type
- CJPJ85/SC: XLPE insulated crosslinked polyolefin inner sheath Copper wire braided armoring crosslinked polyolefin outer sheath marine power cable type SC
- CJPJ95/SC: XLPE insulated crosslinked polyolefin inner sheathed wire braided armoring crosslinked polyolefin outer sheathed marine power cable Type SC
- CJV82/DNSA: XLPE insulated PVC inner sheathed copper wire braided armored PVC outer sheathed marine power cable DA/SA type
- CJV92/DNSA: XLPE insulated PVC inner sheathed wire braided armored PVC outer sheathed marine power cable DA/SA type
Product Application
This product is suitable for the use of electric power devices in water structures such as cabins and offshore oil platforms.
Cable Parameters
| Crosslinked Polyethylene Insulated Marine Power Cable at rated voltage of 6/10KV |
No.of cores
×sectional
area |
CJPJ/SC CJV/DASA |
CJPJ85/SC CJPJ95/SC CJV82/DASA CJV92/DASA |
| Over diam.mm |
Approx.
weight |
Over diam.mm |
Approx.weight |
| Nom. |
Max |
Nom. |
Max |
TYPE 82/85 |
TYPE 92/95 |
| 1×16 |
18.0 |
20.7 |
517 |
21.0 |
24.1 |
764 |
752 |
| 1×25 |
19.4 |
22.3 |
638 |
23.0 |
26.4 |
926 |
913 |
| 1×35 |
20.6 |
23.6 |
769 |
24.2 |
27.8 |
1072 |
1058 |
| 1×50 |
21.8 |
25.0 |
914 |
25.6 |
29.4 |
1248 |
1233 |
| 1×70 |
23.6 |
27.1 |
1162 |
27.6 |
31.7 |
1555 |
1536 |
| 1×95 |
25.5 |
29.3 |
1460 |
29.7 |
34.1 |
1898 |
1877 |
| 1×120 |
26.7 |
30.7 |
1711 |
30.9 |
35.5 |
2168 |
2146 |
| 1×150 |
28.5 |
32.7 |
2022 |
32.7 |
37.6 |
2507 |
2483 |
| 1×185 |
30.1 |
34.6 |
2393 |
34.5 |
39.6 |
2922 |
2897 |
| 1×240 |
32.7 |
37.6 |
2990 |
37.1 |
42.6 |
3561 |
3534 |
| 1×300 |
35.0 |
40.2 |
3620 |
39.6 |
45.5 |
4250 |
4222 |
| 3×16 |
36.4 |
41.9 |
1989 |
41.2 |
47.4 |
2674 |
2644 |
| 3×25 |
39.6 |
45.6 |
2468 |
44.4 |
51.1 |
3209 |
3176 |
| 3×35 |
42.0 |
48.3 |
2922 |
47.0 |
54.1 |
3730 |
3695 |
| 3×50 |
44.8 |
51.5 |
3477 |
50.0 |
57.5 |
4362 |
4325 |
| 3×70 |
48.4 |
55.7 |
4347 |
53.6 |
61.7 |
5299 |
5260 |
| 3×95 |
52.3 |
60.1 |
5386 |
57.9 |
66.6 |
6514 |
6463 |
| 3×120 |
55.3 |
63.6 |
6322 |
61.1 |
70.2 |
7544 |
7490 |
| 3×150 |
58.9 |
67.8 |
7412 |
64.9 |
74.7 |
8746 |
8688 |
| 3×185 |
62.6 |
72.0 |
8746 |
69.2 |
79.5 |
10369 |
10287 |
| Note: Data above only for reference.confirmation needed by our technical department. We reserve the right to alter all information without notice. |
Main Technical Characteristics
- The rated voltage of the cable is 3.6/6(7.2)kV, 6/10(12)kV, 8.7/15(17.5)kV
- The allowable long-term operating temperature of the cable conductor is 90°C
- The flame retardant performance of the cable conforms to IEC60332-1-2/IEC60332-3-22 standard
- The fire resistance of the cable conforms to IEC60331-21 standard
- The minimum bending radius of a single-core cable is 12 times the outer diameter of the cable, and the minimum bending radius of a 3-core cable is 9 times the outer diameter of the cable
Identification
- The insulation core is identified by color tape
- Sheath printed with factory name, type, voltage, specification, length mark, etc.
Structure Diagram