Crosslinked Polyethylene Insulated Marine Power Cable with 8.7/15kV Rated Voltage and Flame Retardant Properties
Crosslinked Polyethylene Insulated Marine Power Cable
Rated voltage: 8.7/15kV
Executive Standard
This product implements IEC60092-354 standard.
Cable Types and Specifications
- CJPJ/SC: XLPE insulated crosslinked polyolefin outer sheathed Marine power cable type SC
- CJV/DNSA: XLPE insulated PVC sheathed marine power cable DA/SA type
- CJPJ85/SC: XLPE insulated crosslinked polyolefin inner sheath, copper wire braided armoring, crosslinked polyolefin outer sheath marine power cable type SC
- CJPJ95/SC: XLPE insulated crosslinked polyolefin inner sheathed wire braided armoring crosslinked polyolefin outer sheathed marine power cable Type SC
- CJV82/DNSA: XLPE insulated PVC inner sheathed copper wire braided armored PVC outer sheathed marine power cable DA/SA type
- CJV92/DNSA: XLPE insulated PVC inner sheathed wire braided armored PVC outer sheathed marine power cable DA/SA type
Product Application
This product is suitable for electric power devices in water structures such as cabins and offshore oil platforms.
Cable Parameters
| Crosslinked Polyethylene Insulated Marine Power Cable at rated voltage of 8.7/15kV |
No.of cores
×sectional
area |
CJPJ/SC CJV/DASA |
CJPJ85/SC CJPJ95/SC CJV82/DASA CJV92/DASA |
| Over diam.mm |
Approx.
weight |
Over diam.mm |
Approx.weight |
| Nom. |
Max |
Nom. |
Max |
TYPE 82/85 |
TYPE 92/95 |
| 1×25 |
21.8 |
25.0 |
738 |
25.6 |
29.4 |
1072 |
1057 |
| 1×35 |
23.0 |
26.4 |
873 |
27.0 |
31.0 |
1257 |
1238 |
| 1×50 |
24.2 |
27.8 |
1023 |
28.2 |
32.4 |
1425 |
1405 |
| 1×70 |
26.0 |
29.9 |
1279 |
30.2 |
34.7 |
1724 |
1703 |
| 1×95 |
27.7 |
31.8 |
1569 |
31.9 |
36.6 |
2041 |
2018 |
| 1×120 |
29.1 |
33.4 |
1840 |
33.5 |
38.5 |
2353 |
2329 |
| 1×150 |
30.9 |
35.5 |
2158 |
35.3 |
40.5 |
2700 |
2674 |
| 1×185 |
32.5 |
37.3 |
2535 |
36.9 |
42.4 |
3102 |
3076 |
| 1×240 |
35.1 |
40.3 |
3142 |
39.7 |
45.6 |
3774 |
3745 |
| 1×300 |
37.4 |
43.0 |
3782 |
42.2 |
48.5 |
4475 |
4445 |
| 3×25 |
44.8 |
51.5 |
2940 |
49.8 |
57.3 |
3797 |
3760 |
| 3×35 |
47.1 |
54.2 |
3417 |
52.5 |
60.4 |
4412 |
4365 |
| 3×50 |
49.9 |
57.4 |
4000 |
55.5 |
63.9 |
5081 |
5031 |
| 3×70 |
53.6 |
61.6 |
4908 |
59.4 |
68.3 |
6094 |
6042 |
| 3×95 |
57.4 |
66.0 |
5986 |
63.4 |
72.9 |
7288 |
7231 |
| 3×120 |
60.4 |
69.5 |
6952 |
66.8 |
76.8 |
8486 |
8407 |
| 3×150 |
64.1 |
73.7 |
8079 |
70.7 |
81.3 |
9738 |
9654 |
| 3×185 |
67.7 |
77.9 |
9450 |
74.5 |
85.7 |
11240 |
11151 |
| Note: Data above only for reference.confirmation needed by our technical department. We reserve the right to alter all information without notice. |
Technical Characteristics
- Rated voltage: 3.6/6(7.2)kV, 6/10(12)kV, 8.7/15(17.5)kV
- Allowable long-term operating temperature of cable conductor: 90°C
- Flame retardant performance conforms to IEC 60332-1-2 and IEC 60332-3-22 standards
- Fire resistance conforms to IEC 60331-21 standard
- Minimum bending radius: single-core cable - 12 times cable outer diameter; 3-core cable - 9 times cable outer diameter
Cable Identification
Insulation core identified by color tape; sheath printed with factory name, type, voltage, specification, length mark, etc.
Cable Structure Diagram