| Cable Type | Cat5e Snagless |
| Shielding Type | Unshielded (U/UTP) |
| Cable Jacket | PVC CM (Round) |
| Length | 3ft (0.9m) Including Plugs |
| Data Rate Support | 10/100/1000Base-T |
| Standard Bandwidth | 100MHz |
| Conductor Type | Stranded Pure Bare Copper |
| Connectors | RJ45 (Male) |
| Gauge (AWG) | 24 (7/0.20mm) |
| Cable Outer Diameter | 5.5± 0.4mm |
| PoE Compatibility | PoE/PoE+ |
| Wire Scheme | T568B, Straight |
| Operating Temperature | -20°C to +75°C (-4°F to 167°F) |
| Installation Temperature | -10°C to +50°C (14°F to 122°F) |
| Cable Type | Cat6 Snagless |
| Shielding Type | Unshielded (U/UTP) |
| Cable Jacket | PVC CM (Round) |
| Length | 3ft (0.9m) Including Plugs |
| Data Rate Support | 1000Base-T and Maximum to 10GBase-T |
| Standard Bandwidth | 250MHz |
| Conductor Type | Stranded Pure Bare Copper |
| Connectors | RJ45 (Male) |
| Gauge (AWG) | 24 (7/0.20mm) |
| Cable Outer Diameter | 6.1 ± 0.4mm |
| PoE Compatibility | PoE/PoE+ |
| Wire Scheme | T568B, Straight |
| Operating Temperature | -20°C to +75°C (-4°F to 167°F) |
| Installation Temperature | -10°C to +50°C (14°F to 122°F) |
| Parameter | PVC | LSZH Low Smoke Halogen-Free |
|---|---|---|
| Tensile strength before aging | ≥13.5Mpa | ≥10.0Mpa |
| Elongation before aging | ≥150% | ≥125% |
| Aging time | 100℃ * 24 hours * 7 days | |
| Tensile strength after aging | ≥12.5Mpa | ≥8Mpa |
| Elongation after aging | ≥125% | ≥100% |
| Cold bending (-20±2℃ * 4 hours) | 8 times the outer diameter of the cable without cracking | |
| Transmission delay difference | ≤25ns / 100m |
| Transmission speed | 74% |
| Unbalanced capacitance to ground | Maximum 330pf / 100m |
| DC resistance | Maximum 9.5Ω / 100m |
| DC resistance unbalance | Maximum 2% |
| Brand | LINKE | Cross Section (mm²) | 0.01-500mm² |
| Wire Gauge (AWG) | [e.g., 24AWG, 28AWG] | Conductor | Tinned Copper /bare copper, based on client's requirements |
| Insulation material | PVC/TPU/Silicone rubber/PE/PP/XLPE/Nylon/other | Jacket Material | [PVC/PU/Rubber/Braid/etc.] |
| Certifications | RoHS/REACH/UL/CE/IP68/etc | Custom Length | [e.g., 1m, 3ft, 5m ±5% tolerance] |
| Cable Type | [Medical/Power/Audio/Coaxial/Electrical/Automotive/Energy storage//etc.] | Shielding | [Shielded/Unshielded/Braid Shield] |
| Impedance | [e.g., 75Ω (for coaxial cables)] | Printing/Logo | [Text/Label/Logo, max. 20 characters] |
| Bend Radius | [e.g., ≥5× cable diameter] | Current Rating | [e.g., 5A] |
| Voltage Rating | [e.g., 30V AC/DC] | Connector Material | [Gold-plated/Nickel-plated/Brass/etc.] |
| Connectors | [e.g., USB Type-C, 3.5mm Jack, RJ45] | Jacket | XLPE or PE or PVC RUBBER |
| Delivery Time | 7-14 days after confirming the order | Colors | [Black/White/Red/Custom Pantone/etc.] |
| temperature | Minus-70℃to 350℃(-70℃ ~ 350℃) | Package | Roll/box/plate/Custom |
| Supporting Services | multicolumn {3}{l}{custom cable, end to end solutions, including precise cutting, crimping and installation of lugs (specify material,e.g.,copper/nickel plated) |
| No. | Test Item | Test Condition | Test Requirement | Test Data | Result |
| 1 | Structure Inspection | 1. Comply with wire size table2. Minimum thickness ≥ 80% of average thickness | Comply with wire size table | Refer to test record | Pass |
| 2 | Thermal Shock | Wind the sample on an iron rod of specified size, place in an aging oven at specified temperature for 1 hour, cool the sample to room temperature for at least 30 minutes, then observe the sample | No cracks on the sample surface | No cracks | Pass |
| 3 | Heat Deformation | 1. Measure sample thickness (mark measurement position)2. Place sample and test fixture in aging oven for preheating at specified temperature for 1 hour3. Place sample under pressure column of test fixture for 1 hour4. Re-measure sample thickness at the same position | 1. Sample shall not be cracked by pressure column or expose conductor2. Thickness reduction ≤ 50% | Refer to test record | Pass |
| 4 | FT2 | Apply a standard flame at a height of 125mm once | 1. Flame shall not propagate along its length2. Flame shall not spread to nearby flammable materials | Refer to test record | Pass |
| 5 | Aging | 1. Take five sections of 200mm-long sheath2. Place specimens in aging oven at 158℃ for 168 hours3. After taking out specimens, place at room temperature 23±5℃ for 16 hours, then test elongation at break and tensile strength | 1. Elongation before aging ≥ 300%, elongation after aging ≥ 80% of that before aging2. Tensile strength before aging > 1.41kg/mm², tensile strength after aging ≥ 80% of that before aging | Refer to test record | Pass |
| 6 | Cold Bend | Store sample in low-temperature box at specified temperature for 4 hours, wind sample on iron rod of specified size with specified turns, complete winding within 30 seconds after sample is taken out of low-temperature box | No cracks on the sample surface | No cracks | Pass |
| 7 | Conductor Resistance | Measure resistance of one-meter core conductor with DC resistance meter | At 20℃, resistance of 8AWG ≤ 2.23Ω/km | Refer to test record | Pass |