It is applicable in testing all kinds of suspending pulp liquid that less than 100°SR--- Schopper-Riegler. It can utilize the material economically with manual controlling and operate easily. Its parameters and performance accord with the standards QB/T1054-98, GB/T3332-1982 and ISO5267/1.
| Item | Description |
|---|---|
| Measurement Range | (1-100°) SR |
| Minimum Scale | 1°SR |
| Temperature of Distilled Water | 20±0.5 °C |
| Draining Time | 149±1 s |
| Volume of Distilled Water | 1000ml |
| Residual Volume | (7.5-8)ml |
| Size | 460*250mm |
| Standard Accessories | Measuring cylinder(2pcs), Copper net(1pc), Rubber gasket(1pc), Frame(1pc) |