Switch element: microswitch, mercury-free, Limit value detection for fluids, Ball design: high buoyancy
Technical Data
|   			 Electrical specifications  |   		||
|---|---|---|
|   			 Contact loading  |   			  			 250 V AC/3 A; 150 V DC/0.25 A resistive load; 60 V DC/1 A resistive load  |   		|
|   			 Rated insulation voltage  |   			  			 300 V  |   		|
|   			 Pulse withstand voltage  |   			  			 4 kV  |   		|
|   			 Electrical life  |   			  			 ≥ 5 x 104 switching cycles  |   		|
|   			 Directive conformity  |   		||
|   			 Low voltage  |   			  			 
  |   		|
|   			 
  |   			  			 Directive 2014/35/EU  |   			  			 EN 60947-5-1:2004 + Cor.:2005 + A1:2009  |   		
|   			 Conformity  |   		||
|   			 Degree of protection  |   			  			 IEC 60529:2001  |   		|
|   			 Application  |   		||
|   			 Description  |   			  			 microswitch with switching ball, change-over contact  |   		|
|   			 Function and system design  |   		||
|   			 Equipment architecture  |   			  			 This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.  |   		|
|   			 Operating conditions  |   		||
|   			 Installation conditions  |   			  			 
  |   		|
|   			 
  |   			  			 Installation instructions  |   			  			 range of application and minimum length between mounting and float:  |   		
|   			 Process conditions  |   			  			 
  |   		|
|   			 
  |   			  			 Process pressure (static pressure)  |   			  			 ≤ 2 bar (29 psi) at 20 °C (68 °F)  |   		
|   			 
  |   			  			 Density  |   			  			 ≥ 0.6 g/cm3  |   		
|   			 Ambient conditions  |   		||
|   			 Ambient temperature  |   			  			 5 ... 70 °C (41 ... 158 °F)  |   		|
|   			 Storage temperature  |   			  			 -25 ... 70 °C (-13 ... 158 °F)  |   		|
|   			 Altitude  |   			  			 ≤ 2000 m above MSL  |   		|
|   			 Mechanical specifications  |   		||
|   			 Degree of protection  |   			  			 IP68  |   		|
|   			 Cable  |   			  			 
  |   		|
|   			 
  |   			  			 Length  |   			  			 5 m  |   		
|   			 Mechanical construction  |   		||
|   			 Material  |   			  			 float: PP (Polypropylene)  |   		|
|   			 Switching point  |   			  			 switch angle, measured against the horizontal:  |   		|
  Related Models:
|   			 KFU8-UFT  |   			  			 KFD0-CS-Ex1.51P  |   		
|   			 K-HM26-2M-261533  |   			  			 KFD0-CS-Ex2.50P  |   		
|   			 NBB15-U1-E2  |   			  			 KFD0-CS-Ex2.51P  |   		
|   			 NBB1,5-5GM25-E2  |   			  			 KFD0-RO-Ex2  |   		
|   			 NBB1,5-5GM25-E2-V3  |   			  			 KFD0-SCS-Ex1.55  |   		
|   			 NBB1,5-F79-E0  |   			  			 KFD0-SD2-Ex2.1045  |   		
|   			 NBB1,5-F79-E2  |   			  			 KFD0-SD2-Ex2.1245  |   		
|   			 NBB15-U1-Z2  |   			  			 KFD0-TR-Ex1  |   		
|   			 NBB5-18GM50-E2-V1  |   			  			 KFD0-CC-1  |   		
|   			 NBB15-30GM30-E2-V1  |   			  			 KFD0-HMS-16  |   		
|   			 NBB15-30GM50-A2-V1  |   			  			 KFD0-RSH-1.4S.PS2  |   		
|   			 NBB15-30GM50-E2  |   			  			 KFD0-SD2-EX1.10100  |   		
|   			 NBB15-30GM50-E2-M  |   			  			 KFD0-SD2-EX1.1045  |   		
|   			 NBB15-30GM50-E2-V1  |   			  			 KFD2-UT2-1  |   		
|   			 NBB15-30GM50-E2-V1-M  |   			  			 KFD2-CD-1.32  |   		
|   			 NBB8-18GM30-E2  |   			  			 KFD2-CD-EX1.32  |   		
|   			 NBB8-18GM30-E2-V1  |   			  			 KFD2-HMM-16  |   		
|   			 NBB8-18GM60-A2-V1  |   			  			 KFD2-SH-EX1.T  |   		
|   			 NJ4-12GK-SN  |   			  			 KFD2-UT2-1  |   		
|   			 NJ5-18GK-N  |   			  			 KFD2-VR4-EX1.26  |   		
|   			 NJ5-18GK-N-150  |   			  			 KFU8-UFC-1.D  |   		
|   			 NJ5-18GM-N  |   			  			 V15-G-2M  |   		
|   			 NJ8-18GK-N  |   			  			 Z 787  |   		
|   			 RD0-FB-EX4  |   			  			 Z787.H  |   		
|   			 RD0-TI-Ex8.FF.*  |   			  			 HIC2031  |   		
|   			 Z787.F  |   			  			 Z787.H.F  |   		