I. Core Features
- Direct-acting linear force motor drive: No pilot oil required, dynamic performance is pressure-independent, fast response, and anti-contamination.
- Integrated electronics + valve core closed-loop: Built-in amplifier with valve core position feedback, high control accuracy, and low hysteresis.
- Low power consumption: Low current consumption in and around the neutral position, energy saving.
- Fail-safe: When power is lost, the valve core spring returns to the neutral position, and the system shuts down safely.
- Installation standard: ISO 4401 specification 05 (NG10), flange mounting.
II. Key Technical Parameters
Hydraulic Parameters
- Rated flow rate: 100 l/min (Δp = 35 bar / per throttle edge)
- Maximum working pressure: P/A/B port 350 bar; T port 210 bar
- Working medium: Petroleum-based hydraulic oil (DIN 51524), viscosity 5–400 mm²/s
- Temperature range: Ambient -20℃~+60℃; Oil -20℃~+80℃
- Step Response: 0–100% Stroke ≤20 ms
- Hysteresis: ≤0.2%
- Weight: Approx. 5.7 kg
Electrical Parameters
- Power Supply: 24 VDC (19–32 VDC)
- Control Signals: ±10 V, ±10 mA, 4–20 mA (optional)
- Protection Rating: Connector IP65Moog
III. Typical Applications
- Injection Molding Machines, Die Casting Machines, Servo Presses, Testing Machines
- Rolling Mills, Plastics Machinery, Hydraulic Test Benches
- Industrial hydraulic systems requiring high dynamics and high-precision closed-loop control
IV. Installation and Maintenance
- Installation: ISO 4401-05 flange, M6 bolts, torque 13 Nm
- Filtration: Oil cleanliness ISO 4406 16/13 and above, high-pressure filter recommended
- Seal: Standard NBR, FKM optional