| RH005 | RH-5 | 7.5 | 0.5 to 6.75K | 0.1 to 8.6K | 0.05 to 8.6K | 0.02 to 24.5K | 3 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH005 | NH-5 | 7.5 | 0.5 to 2.32K | 0.1 to 3.27K | 0.05 to 3.27K | 0.05 to 12.75K | 3 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| RH010 | RH-10 | 12.5 | 0.5 to 12.7K | 0.1 to 16.69K | 0.05 to 16.69K | 0.01 to 47.1K | 5 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH010 | NH-10 | 12.5 | 0.5 to 4.45K | 0.1 to 5.54K | 0.05 to 5.54K | 0.05 to 23.5K | 5 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| RH025 | RH-25 | 25 | 0.5 to 25.7K | 0.1 to 32.99K | 0.05 to 32.99K | 0.01 to 95.2K | 12 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH025 | NH-25 | 25 | 0.5 to 9.09K | 0.1 to 12.8K | 0.05 to 12.8K | 0.05 to 47.6K | 12 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| RH050 | RH-50 | 50 | 0.5 to 73.4K | 0.1 to 96K | 0.05 to 96K | 0.01 to 273K | 28 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH050 | NH-50 | 50 | 0.5 to 26K | 0.1 to 36.7K | 0.05 to 36.7K | 0.05 to 136K | 28 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| RH100 | RH-100 | 100 | 0.5 to 90K | 0.1 to 90K | 0.05 to 90K | 0.05 to 90K | 353 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH100 | NH-100 | 100 | 0.5 to 37.5K | 0.1 to 37.5K | 0.05 to 37.5K | 0.05 to 37.5K | 353 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| RH250 | RH-250 | 250 | 0.5 to 116K | 0.1 to 116K | 0.05 to 116K | 0.05 to 116K | 637 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH250 | NH-250 | 250 | 0.5 to 48.5K | 0.1 to 48.5K | 0.05 to 48.5K | 0.05 to 48.5K | 637 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |