Portable Coal Gas Analyzer KGD - MQ - 513
Product Introduction
The Portable Coal Gas Analyzer KGD - MQ - 513 adopts non - dispersive infrared (NDIR) gas analysis technology with independent intellectual property rights, long - life electrochemical sensing technology, and MEMS - based thermal conductivity technology. It can simultaneously measure the calorific values of coal gas and biogas, as well as the volume concentrations of gases such as CO, CO₂, CH₄, H₂, O₂, and CₙHₘ.

Product Features
- Simultaneously measures gas components and calorific values: It can simultaneously measure the volume concentrations of gases such as CO, CO₂, CH₄, H₂, O₂, and CₙHₘ, and automatically calculate and display the calorific values of coal gas and natural gas, replacing the combustion - type calorific value meter.
- High measurement accuracy: No cross - interference among multi - component measured gases: CₙHₘ has no interference on the measurement result of CH₄, and CO, CO₂, and CH₄ have no interference on the measurement result of H₂. It is less affected by the outside world, and the change of gas sampling flow has no impact on the measurement result of the H₂ thermal conductivity sensor. Measuring the volume concentration of CₙHₘ ensures the accuracy of the calorific values of gases such as coke oven gas, mixed gas, producer gas, and straw gas.
- Portable body design: Easy to carry, it can meet the needs of both on - site industrial measurement and laboratory airbag sampling analysis.
- Intelligent power management: Soft - start power switch and intelligent battery power management avoid the instrument from operating under low - power conditions.
- Simple data management: Automatically stores measurement data, with query and deletion functions, and can transmit data to the superior centralized control system through multiple interfaces.
- Low cost of use: Compared with gas analysis technologies such as Orsat and chromatography, the measurement process does not require disassembly and installation, consumption of chemical reagents, etc. It has a simple structure, is easy to operate, and has no consumables.
Technical Parameters
Measured Components | CO/CO₂/CH₄/H₂/O₂/C₂H₂/C₂H₄/CₙHₘ*/Calorific Value |
Measurement Principle | CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: NDIR; H₂: TCD; O₂: ECD |
Measurement Range | CO/CO₂/CH₄/H₂: (0 - 100)% |
O₂: (0 - 25)%; C₂H₂/C₂H₄/CₙHₘ: (0 - 10)% (Optional) |
Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: ±1%F.S.; O₂/H₂: ±2%F.S. |
Resolution | ≤ 0.01% |
Repeatability | ≤ 1% |
Response Time | T90 < 15s (NDIR) |
Optimal Flow Rate | (0.7 - 1.2) L/min |
Inlet Pressure | (2 - 50) kPa |
Gas Requirements | Dust - free, water - free, oil - free |
External Dimensions | 412152294 (mm) |
Weight | 9kg |
Electrical Parameters | Electrical Parameters |
Communication | RS - 232 |
Power Supply | Powered by built - in rechargeable lithium - ion battery, with an external 12.6V charger |
Display | LCD Display |
Functional Configuration | Built - in sampling air pump |
Optional pretreatment device |
Calorific value units Kcal/m³ and MJ/m³ can be freely switched |
Self - diagnosis function available for on - line inspection of sensor status |
Note | CₙHₘ represents the sum of other hydrocarbons except methane. |