Specifications
Brand Name :
KACISE
Model Number :
KGD-MQ-511
Certification :
CE
Place of Origin :
CHINA
MOQ :
1PCS
Payment Terms :
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability :
1000 Piece/Pieces per Week negotiable
Delivery Time :
5-8 work days
Packaging Details :
each unit has individual box and all boxes are packed in standard packages or customers requests available
Component Range :
O₂: 0 - 25%; COe: 0 - 10000ppm
Response Time :
O₂: T90 ≤ 10s; COe: T90 ≤ 20s
Measurement Accuracy :
O₂: ±1.0%F.S. or 0.2%; COe: ±5%F.S. or 25ppm
Resolution :
O₂: 0.01%COe: 1ppm
Communication Method :
RS - 485/MODBUS
Output :
2 - way 4 - 20mA, 3 - way adjustable alarm
Description

In - situ Zirconia Gas Analyzer KGD - MQ - 511

Product Introduction

The In - situ Zirconia Gas Analyzer KGD - MQ - 511 is a high - temperature analyzer for oxygen and combustible gas COe. It can simultaneously monitor the contents of oxygen and combustible gas, and control the combustion efficiency at an optimal level. Based on the principles of zirconia limiting current and thick - film catalysis, it is installed with a flange and measures gas through a flow - guiding method. It can maintain continuous and real - time stable monitoring in harsh environments such as high temperature and high dust.

In - Situ Zirconia Gas Analyzer KGD - MQ - 511

Product Features

  • Simultaneously measures oxygen and combustible gas COe with high precision.
  • Wide measurement temperature range, up to 1500°C at most.
  • The sensor is treated with constant temperature to avoid the influence of ambient temperature and inlet gas temperature.
  • The sampling probe rod is equipped with a filter and a baffle design, enabling use under high - dust conditions.

Technical Parameters

Main Parameters
Component Range O₂: 0 - 25%; COe: 0 - 10000ppm
Response Time O₂: T90 ≤ 10s; COe: T90 ≤ 20s
Measurement Accuracy O₂: ±1.0%F.S. or 0.2%; COe: ±5%F.S. or 25ppm
Resolution O₂: 0.01%COe: 1ppm
Communication Method RS - 485/MODBUS
Output 2 - way 4 - 20mA, 3 - way adjustable alarm
Ambient Temperature Control Unit: -40°C - 65°C; Sensor Unit: -40°C - 120°C
Protection Grade IP66
Probe Material S316L, Alloy 600, Alumina, with customizable length
Installation Flange DN50 customizable
Send your message to this supplier
Send Now

In - Situ Zirconia Gas Analyzer KGD - MQ - 511

Ask Latest Price
Brand Name :
KACISE
Model Number :
KGD-MQ-511
Certification :
CE
Place of Origin :
CHINA
MOQ :
1PCS
Payment Terms :
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact Supplier
In - Situ Zirconia Gas Analyzer KGD - MQ - 511

Xi'an Kacise Optronics Co.,Ltd.

Verified Supplier
7 Years
Shaanxi
Since 2008
Business Type :
Manufacturer
Total Annual :
8000000-10000000
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement