ISO 11507 Accelerated Weathering Chamber Type UV Aging Test Chamber
Complied Standards & Clauses
Conforms to ISO 11507, ISO4892-3, ASTM G154, ASTM G153, ASTM4329, IEC 61215, etc.
Equipment Overview
Technical Parameters
| Model | SN882B |
| Sample size | WDH=1100*600*500(mm) Inner size sample |
| Sample placement area | Chamber type WDH=1140*600*500(mm) |
| Shape space | About 1400*1750*750(mm)W×H ×D |
| Center distance in the lamp | 70mm |
| Distance between the test surface of the sample and the center of the lamp | 50±3 mm |
| Nozzle quantity | Top row 4 pcs |
| Spraying pressure | 70~200Kpa adjustable |
|
UV-B Lamp irradiation distribution diagram |
1.Standard machine irradiation intensity 0~0.9 is W/m2.313nm, adjustable |
|
UV-A lamp irradiation distribution diagram |
1. Standard machine irradiation intensity is 0~0.9W/m2.340nm, adjustable
|
| Lamp length | 1220mm |
| Lamp power | 40W |
| Lamp lifespan | More than 1600h |
| Number of lamps | 8 pcs lamps in the top row Ultraviolet lamps can be selected from UV-A / UV-B lamps. If there is no special instruction, the machine is equipped with UV-A lamps when leaving the factory |
| Weight | 80 kg |
| Maximum power | 3 KW |
| Maximum current | 15A |
| Performance indicators | |
| Operating environment conditions | The values are measured when the ambient temperature is +25℃, the relative humidity is ≤85%, and there is no test sample in the test chamber. |
| Temperature and humidity range | Irradiation temperature: 50~ 70℃ Condensation temperature: RT~ 60℃ Spraying temperature: room temperature Relative humidity: Condensation cycle ≥85%RH; Irradiation cycle ≦75%RH |
| Main technical parameters | Temperature resolution: 0.01℃ Temperature deviation: ±1℃ Temperature uniformity: 2℃ Temperature fluctuation: ±1℃ |
| Heating rate | Irradiation temperature RT→+70℃≤45 min Condensation temperature RT→+60℃≤45 min |