Specifications
Brand Name :
Sinuo
Model Number :
SN8810-718L
Certification :
Calibration Certificate (Cost Additional)
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T
Supply Ability :
10 Sets Per Month
Delivery Time :
30 Days
Packaging Details :
Export packing
Maximum power :
3KW
Maximum current :
14A
Nominal internal volume :
718L
Inner box size :
98×63.5×115.5(L×W×H) cm
Outline space :
180×85×190(L×W×H) cm
Equipment weight :
250kg
Test room temperature :
RT~50℃
Pressure barrel temperature :
RT~ 63℃
Description

IEC 60068-2-11 Salt Spray Machine Accelerated Corrosion Testing Equipment

Complied Standards & Clauses


Test compliance and product implementation standards: conform to T2423.17-2008/IEC 60068-2-11-1981, JIS H8502, T10125-2012/ISO 9227-2006, ISO9227, GJB-150.11A-2009.

Product Overview


The SN8810-718L Salt Spray Test Chamber is a high-performance corrosion testing equipment designed to simulate harsh environments for evaluating the corrosion resistance of coatings, paints, metal parts, and surface treatments. Compliant with international standards such as IEC 60068-2-11, ASTM B117, ISO 9227, and JIS H8502, this chamber ensures accurate and repeatable results for both neutral salt spray and acid salt spray testing.

With an internal volume of 718 liters, advanced PLC touch screen control, and a fully automatic mist exhaust system, the SN8810-718L is engineered for high stability, easy operation, and long-term reliability. It is ideal for automotive, electronics, aerospace, and surface treatment industries.

Technical Parameters


Nominal internal volume 718L
Effective size of inner box (cm) 98×63.5×115.5(L×W×H) cm
Outline space (cm) Approx. 180×85×190(L×W×H) cm
Weight About 250kg
Maximum power 3KW
Maximum current 14A
Power supply
Power supply conditions and power supply

1. AC 220V single-phase two-wire + protective grounding; allowable voltage fluctuation range ±10%V;

2. The allowable frequency fluctuation range is 50±0.5HZ; TN-S mode power supply or TT mode power supply.

3. The grounding resistance of the protective ground wire is less than 4Ω

4. The user is required to configure an air or power switch of corresponding capacity for the equipment at the installation site, and this switch must independently control the use of the equipment. at the installation site, and this switch must independently control the use of the equipment.

Performance index
Use environmental conditions

1. The ambient temperature is 5~30℃ and the relative humidity is ≤85%R.H;

2. The installation site must be a flat, vibration-free ground;

3. The equipment needs to be kept away from heat sources and flammable and explosive substances;

4. The installation location must not be exposed to direct sunlight and maintain indoor air circulation;

5. The equipment installation site needs to be clean and cannot be installed in dusty places or dust exhaust outlets.

Temperature and humidity range

Test room temperature: RT~50℃

Pressure barrel temperature: RT~ 63℃

Relative humidity ≥85%R.H

Heating rate

Test room temperature RT→+50℃≤60 min

Pressure barrel temperature RT→+63℃≤60 min

Main technical parameters

Temperature resolution: 0.1℃

Temperature deviation: ±1℃

Temperature uniformity: 2℃

Temperature fluctuation:±1℃

Spray volume (m1/80cm2/h) 1.0~2.0 (collect at least 16 hours, take the average value)

Spray pressure: 1.00±0.01kgf/cm2

Potion PH value: Neutral 6.0~7.0 Acidic 3.0~3.1

Spray solution pH value: Neutral 6.5~7.2 Acidic 3.1~3.3

Control time: 1S ~ 9999H can be set arbitrarily

Note: The loss of carbon dioxide in the solution during spraying may cause changes in pH value. You can use the following methods, such as heating the solution to above 35°C before placing it in the test equipment, or using fresh boiling water to prepare the solution to reduce the carbon dioxide content in the solution. , can avoid changes in pH value. In order to ensure the pH value of the spray solution in the acid test or copper accelerated salt spray test, the pH value of the configured potion can be adjusted to 2.8~3.0 and check whether the solution and/or solute meets the requirements. it into the test equipment, or using fresh boiling water to prepare the solution to reduce the carbon dioxide content in the solution, which can avoid the change of pH value. The acid test or copper accelerated salt spray test is to ensure the pH value of the spray solution, Adjust the PH value of the solution to 2.8~3.0 and check whether the solution and/or solute meet the requirements.

Details


IEC 60068-2-11 Salt Spray Machine Accelerated Corrosion Testing EquipmentIEC 60068-2-11 Salt Spray Machine Accelerated Corrosion Testing Equipment

Send your message to this supplier
Send Now

IEC 60068-2-11 Salt Spray Machine Accelerated Corrosion Testing Equipment

Ask Latest Price
Watch Video
Brand Name :
Sinuo
Model Number :
SN8810-718L
Certification :
Calibration Certificate (Cost Additional)
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T
Contact Supplier
video
IEC 60068-2-11 Salt Spray Machine Accelerated Corrosion Testing Equipment
IEC 60068-2-11 Salt Spray Machine Accelerated Corrosion Testing Equipment
IEC 60068-2-11 Salt Spray Machine Accelerated Corrosion Testing Equipment
IEC 60068-2-11 Salt Spray Machine Accelerated Corrosion Testing Equipment
IEC 60068-2-11 Salt Spray Machine Accelerated Corrosion Testing Equipment

Sinuo Testing Equipment Co. , Limited

Verified Supplier
4 Years
guangdong, guangzhou
Since 2019
Business Type :
Manufacturer
Employee Number :
<100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement