Product characteristics
| Electrical design |
PNP |
| Output function |
normally open / closed; (configurable) |
| Sensing range [mm] |
250...3500; (Target: 200 x 200 mm) |
| Communication interface |
IO-Link |
| Housing |
Threaded type |
| Dimensions [mm] |
M30 x 1.5 / L = 103 |
Electrical data
| Operating voltage [V] |
10...30 DC |
| Current consumption [mA] |
< 30 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
< 0.3 |
| Converter frequency [kHz] |
112 |
Inputs / outputs
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analog outputs: 1 |
Outputs
| Total number of outputs |
2 |
| Output signal |
switching signal; analog signal; IO-Link |
| Electrical design |
PNP |
| Number of digital outputs |
1 |
| Output function |
normally open / closed; (configurable) |
| Max. voltage drop switching output DC [V] |
2.2 |
| Permanent current rating of switching output DC [mA] |
100 |
| Switching frequency DC [Hz] |
1 |
| Number of analog outputs |
1 |
| Analog current output [mA] |
4...20 |
| Max. load [Ω] |
500 |
| Short-circuit protection |
yes |
| Overload protection |
yes |
Monitoring range
| Sensing range [mm] |
250...3500; (Target: 200 x 200 mm) |
| Blind zone [mm] |
250 |
| Angle of aperture cylindrical [°] |
12; (±2) |
| Max. deviation from the 90° angle sensor/object [°] |
± 4 |
Accuracy / deviations
| Temperature compensation |
yes |
| Hysteresis [%] |
< 3 |
| Switch-point drift [%] |
-5...5 |
| Linearity error of analog output [%] |
<3 |
| Repeatability |
1 % |
| Resolution [mm] |
3 |
| Notes on the accuracy / deviation |
The indicated values are reached after a warm-up time of min. 20 minutes |
Reaction times
| Response time [ms] |
< 600; (analog output) |
Software / programming
| Parameter setting options |
hysteresis / window; second switch point; Switch-on and switch-off delay; switch-on operations; Teach function; light-on/dark-on mode |
Interfaces
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
Smart Sensor: Device Identification; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Process Data Variable; Device Diagnosis; Teach Channel |
| SIO mode |
yes |
| Required master port class |
A |
| Min. process cycle time [ms] |
3.2 |
| IO-Link process data (cyclical) |
| Function |
bit length |
| process value |
16 |
| device status |
4 |
| binary switching information |
2 |
|
| IO-Link functions (acyclical) |
application specific tag; operating hours counter |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| default |
1094 |
|
| Note |
| For further information please see the IODD PDF file at "Downloads" |
|
Operating conditions
| Ambient temperature [°C] |
-20...70 |
| Storage temperature [°C] |
-30...80 |
| Protection |
IP 67 |
Tests / approvals
| EMC |
| EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated |
3 V/m |
| EN 61000-4-4 Burst |
2 kV |
| EN 61000-4-6 HF conducted |
3 V |
| EN 55011 |
class A |
|
| Vibration resistance |
| EN 60068-2-6 Fc |
(10-55) Hz 1 mm amplitude, vibration duration 5 min., 30 min. per axis with resonance or 55 Hz |
|
| Shock resistance |
| EN 60068-2-27 Ea |
30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
|
| MTTF [years] |
117 |
| UL approval |
| Ta |
-20...70 °C |
| voltage supply |
Class 2 |
| File number UL |
E174191 |
|
Mechanical data
| Weight [g] |
227 |
| Housing |
Threaded type |
| Dimensions [mm] |
M30 x 1.5 / L = 103 |
| Thread designation |
M30 x 1.5 |
| Material |
stainless steel (1.4404 / 316L); PA; epoxy glass ceramics |
| Tightening torque [Nm] |
100 |
Displays / operating elements
| Display |
| Switching status |
2 x LED, yellow |
| echo |
1 x LED, green |
|
| Teach function |
yes |
Accessories
| Items supplied |
| lock nuts: 2, stainless steel |
|
Remarks
| Remarks |
| cULus - Class 2 source required |
|
| Pack quantity |
1 pcs. |
Electrical connection
| Connection |
Connector: 1 x M12; coding: A |