Product characteristics
| Number of inputs and outputs |
Number of analog outputs: 2 |
| Measuring range |
| 0.2...50 l/min |
0.02...13.22 gpm |
|
| Process connection |
threaded connection G 3/4 DN20 flat seal |
Application
| System |
gold-plated contacts |
| Application |
for industrial applications |
| Installation |
connection to pipe by means of an adapter |
| Media |
Conductive liquids; water; water-based media |
| Note on media |
| conductivity: ≥ 20 µS/cm |
| viscosity: < 70 mm²/s (40 °C) |
|
| Medium temperature [°C] |
-10...70 |
| Pressure rating [bar] |
16 |
| Pressure rating [MPa] |
1.6 |
| MAWP (for applications according to CRN) [bar] |
11.2 |
Electrical data
| Operating voltage [V] |
20...30 DC; (to SELV/PELV) |
| Current consumption [mA] |
120; (24 V) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
5 |
Inputs / outputs
| Number of inputs and outputs |
Number of analog outputs: 2 |
Outputs
| Total number of outputs |
2 |
| Output signal |
analog signal |
| Number of analog outputs |
2 |
| Analog current output [mA] |
4...20; (scalable) |
| Max. load [Ω] |
500 |
| Overload protection |
yes |
Measuring/setting range
| Measuring range |
| 0.2...50 l/min |
0.02...13.22 gpm |
|
| Display range |
| -60...60 l/min |
-15.86...15.86 gpm |
|
| Resolution |
|
| Analog start point ASP |
| 0...40 l/min |
0...10.58 gpm |
|
| Analog end point AEP |
| 10...50 l/min |
2.64...13.22 gpm |
|
| In steps of |
|
Temperature monitoring
| Measuring range [°C] |
-20...80 |
| Resolution [°C] |
0.2 |
| Analog start point [°C] |
-20...60 |
| Analog end point [°C] |
0...80 |
| In steps of [°C] |
0.2 |
Accuracy / deviations
Flow monitoring
| Accuracy (in the measuring range) |
± (2 % MW + 0,5 % MEW) |
| Repeatability |
± 0,2% MEW |
Temperature monitoring
| Accuracy [K] |
± 2,5 (Q > 1 l/min) |
Reaction times
Flow monitoring
| Response time [s] |
0.15; (dAP = 0, T19) |
| Damping process value dAP [s] |
0...3 |
Temperature monitoring
| Dynamic response T05 / T09 [s] |
T09 = 20 (Q > 1 l/min) |
Operating conditions
| Ambient temperature [°C] |
-10...60 |
| Storage temperature [°C] |
-25...80 |
| Protection |
IP 67 |
Tests / approvals
| EMC |
| DIN EN 60947-5-9 |
500 V withstand voltage (V DC) |
|
| CPA approval |
| model number |
008MI |
| accuracy class |
- |
| maximum allowable error |
± 2,5 % FS |
| Q (min) |
0,01 m³/h |
| Q (t) |
- |
| Q (max) |
3 m³/h |
|
| Shock resistance |
| DIN IEC 68-2-27 |
20 g (11 ms) |
|
| Vibration resistance |
| DIN IEC 68-2-6 |
5 g (10...2000 Hz) |
|
| MTTF [years] |
175 |
| Pressure equipment directive |
sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight [g] |
521.2 |
| Housing |
tubular |
| Dimensions [mm] |
Ø 54 / L = 110 |
| Material |
stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L); PEEK; FKM |
| Process connection |
threaded connection G 3/4 DN20 flat seal |
Displays / operating elements
| Display |
| Display unit |
6 x LED, green (l/min, m³/h, gpm, gph, °C, °F) |
| Measured values |
alphanumeric display, 4-digit |
| Programming |
alphanumeric display, 4-digit |
|
| Display unit |
l/min; m³/h; gpm; gph; °C; °F |
Remarks
| Remarks |
| MW = Measured value |
| MEW = Final value of the measuring range |
|
| Pack quantity |
1 pcs. |
Electrical connection
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |