Product characteristics
| Output function |
2 x normally open |
| Sensing range [mm] |
4 |
| Housing |
rectangular |
| Dimensions [mm] |
40 x 26 x 26 |
Electrical data
| Frequency AC [Hz] |
47...63 |
| Operating voltage [V] |
20...140 AC / 10...140 DC |
| Protection class |
I |
| Reverse polarity protection |
no |
Outputs
| Output function |
2 x normally open |
| Max. voltage drop switching output DC [V] |
5 |
| Max. voltage drop switching output AC [V] |
5 |
| Minimum load current [mA] |
5 |
| Max. leakage current [mA] |
0.8 |
| Permanent current rating of switching output AC [mA] |
200 |
| Permanent current rating of switching output DC [mA] |
200 |
| Short-time current rating of switching output [mA] |
900; (20 ms / 0,5 Hz) |
| Switching frequency AC [Hz] |
25 |
| Switching frequency DC [Hz] |
25 |
| Short-circuit proof |
no |
| Overload protection |
no |
Monitoring range
| Sensing range [mm] |
4 |
| Real sensing range Sr [mm] |
4 ± 10 % |
| Operating distance [mm] |
0...3.25 |
Accuracy / deviations
| Correction factor |
steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminum: 0.3 / copper: 0.2 |
| Hysteresis [% of Sr] |
3...15 |
| Switch-point drift [% of Sr] |
-10...10 |
Operating conditions
| Ambient temperature [°C] |
-25...80 |
| Protection |
IP 67 |
Tests / approvals
| EMC |
| EN 60947-5-2 |
|
| EN 55011 |
class B |
|
| MTTF [years] |
502 |
Mechanical data
| Weight [g] |
78.5 |
| Housing |
rectangular |
| Mounting |
non-flush mountable |
| Dimensions [mm] |
40 x 26 x 26 |
| Material |
stainless steel (1.4305 / 303); PBT |
Displays / operating elements
| Display |
| Switching status |
2 x LED, red |
|
Electrical connection
| Required protection |
miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area. |
Remarks
| Remarks |
| Recommendation: check the unit for reliable function after a short circuit. |
|
| Pack quantity |
1 pcs. |
Electrical connection - plug
| |
Connector: 1 x 7/8"; coding: A |