The Yaskawa CIMR-AU4A0018FAA is an A1000 high-performance vector variable frequency drive for 380-480 VAC three-phase industrial power systems. It provides a Normal Duty rating of 10 HP at 17.5 A and a Heavy Duty rating of 7.5 to 10 HP at 14.8 A. The applicable duty rating must be selected according to the motor nameplate current, starting torque, acceleration profile, load inertia and operating cycle.
Unlike a basic general-purpose VFD, the A1000 platform supports both open-loop and closed-loop control configurations. With an applicable feedback option and compatible encoder, it can be used in machinery requiring improved speed regulation, torque response and low-speed performance. This makes the CIMR-AU4A0018FAA suitable for conveyors, mixers, winders, extruders, machine tools, process equipment and coordinated production machinery.
| Manufacturer | Yaskawa |
| Complete Model | CIMR-AU4A0018FAA |
| Series | A1000 |
| Product Type | High-Performance Vector VFD |
| Input Power | 380-480 VAC, Three-Phase |
| Normal Duty Rating | 10 HP, 17.5 A |
| Heavy Duty Rating | 7.5 to 10 HP, 14.8 A |
| Overload Capacity | ND 120% for 60 s; HD 150% for 60 s |
| Control Methods | Open/Closed Loop Vector and Open/Closed Loop V/f |
| Supported Motor Types | Induction, SPM and IPM Motors |
| Standard Communication | Modbus RTU, RS-422/485 |
| Enclosure Rating | IP20 / NEMA 1 |
The CIMR-AU4A0018FAA can be operated without encoder feedback for conventional open-loop applications or combined with an appropriate feedback card for closed-loop speed and torque control. Encoder type, signal format, power supply and feedback option must be matched correctly. An encoder cannot be connected directly without confirming the required A1000 option interface.
Normal Duty is generally applicable to pumps, fans and moderate-overload systems. Heavy Duty should be evaluated for loaded conveyors, mixers, extruders and machinery with frequent torque changes. For continuous low-speed operation, confirm motor cooling because a standard self-cooled motor may not dissipate sufficient heat at reduced speed.
Before replacing the drive, verify the complete CIMR-AU4A0018FAA model, specification number, software revision and installed option cards. Back up the parameters and document the power wiring, control terminals, encoder wiring, communication network and braking resistor. Rating-dependent parameters such as motor current, electronic overload protection and tuning data must be reviewed after transfer.
If migrating to GA800, use the official A1000-to-GA800 transition process. Parameter conversion can reduce setup time, but terminal logic, feedback options, safety wiring, network communication, braking hardware and machine-specific functions must be verified separately.
Related models include CIMR-AU4A0011FAA, CIMR-AU4A0023FAA, CIMR-AU4A0031FAA and CIMR-AU4A0038FAA. Select the model according to motor current and required overload capacity rather than nominal horsepower alone.
Please provide the complete drive nameplate, motor nameplate, feedback option, encoder type, communication protocol, braking configuration and required quantity. Final compatibility should be confirmed against the installed machine before ordering.